ELECTRO FREEZE Shake Model CS700-FG
185231-17
13
1. If there is product in the
freezer refer to Section 9.1, CLOSING
PROCEDURES - DRAINING PRODUCT.
2. Make sure all switches are in
the “OFF” position and the freezer is
unplugged.
3. Remove the splash shield figure
6-2a.
Figure 6-2 Dispense Head Assembly
—continued
6.2 Disassembly Instructions
CAUTION
To prevent bacteria growth,
remove ALL O-rings when
disassembling for cleaning.
Failure to do so could create
a health hazard.
CAUTION
To avoid electrical shock
or contact with moving
parts, make sure all
switches are in the “OFF”
position and that the
freezer is unplugged.
4. Pull the keeper (12) out of the
head.
5. Remove spindle assembly (8)
(Refer to figure 6-2). Remove the actuator
rod (7) by lifting up and swinging towards
you.
6. Remove the splash shield bar
(13), handle (10) and hand knobs (14),
then pull the head straight out.