ELECTRO FREEZE Shake Model CS700-FG
185231-17
2
CAUTION
All materials and
connections must conform
to local requirements and
be in compliance with the
National Electric Code (NEC).
CAUTION
To prevent accidental
electrical shock, a receptacle
with a positive earth ground
is required.
1. Always verify electrical
specifications on the data plate (figure
3-2) of each individual freezer. Data plate
specifications will always supersede the
information in this manual.
2. This freezer requires a protected
20 amp 230 volt circuit. Connect the
freezer to a circuit separate from any
other electrical equipment. The power
cord on this freezer connects to a NEMA
6-20R receptacle. See Figure 2-1.
3. Supply voltage must be within
±10% of voltage indicated on the
nameplate. Request your local power
company to correct any voltage problem.
4. The transformer in the electrical
box is factory wired for 240 volts. This
connection maybe used for all voltages
above 200 volts. If the power supply
is less than 200 volts, move the L2
transformer wire connector to the 208 volt
connector.
2.1 Electrical Requirements
3.1 Particulars
3 Specifications
Width
(in/cm)
18.4/46.7
Height
(in/cm)
35.2/89.4
Depth
(in/cm)
28.1/71.4
Weight
(lbs/kg)
220/99.8
Voltage*
208-230/60/1
Min.Circuit Ampacit
y
20.0
Compressor
1 HP/8000 (BTUH)
.75 kw (Motor)
2.3 kw (Cooling)
Beater Motor
1/2 HP/.37 kw
Refrigerant
R-404a
Figure 2-1
Charge
32.0 oz/.91 kg
Cooling
Air
Hopper
20 qts/18.8 liters
Cylinder
7 qts/7.1 liters
*Contact factory for other voltages.