ElectrIQ eiQ-3MS9K9K9K User And Installation Manual Download Page 6

 

 

 

FAN SPEED

  

Use this button to set the fan speed between low, medium, high and automatic (the corresponding symbol 

on the display will flash). The fan speed in the automatic setting is determined by the difference between 

the desired temperature set and the room temperature.  

 
COOLING MODE  

1. 

Repeatedly press the 

MODE

 button until the 

COOL

 indicator appears.  

2. 

Set the desired temperature using the 

TEMPERATURE

 up and down buttons.  

3. 

Use the 

FAN SPEED

 button to set the fan speed.  

 

HEATING MODE 

1. 

Repeatedly press the 

MODE

 button until the 

HEAT

 indicator appears  

2. 

Set the desired temperature using the 

TEMPERATURE

 up and down buttons. 

3. 

Use the 

FAN SPEED

 button to set the fan speed.  

 

FAN MODE  

1. 

Repeatedly press the 

MODE

 button until the 

FAN

 indicator appears.  

2. 

The temperature settings will not affect the fan operation  

3. 

Use the 

FAN SPEED

 button to set the fan speed.  

 

DEHUMIDIFY MODE  

1. 

Repeatedly press the 

MODE

 button until the 

DEHUMIDIFY

 indicator appears.  

2. 

The 

FAN

 button does not work in dehumidify mode. The fan speed will always be low in this mode. 

Also temperature cannot be adjusted in dehumidifying mode  

 
AUTO MODE  

1. 

Repeatedly press the 

MODE

 button until the 

AUTO

 indicator appears. Set the desired temperature 

under auto mode to the required level between 16~32 °C  

2. 

The difference between the set temperature and the room temperature determines how the air 
conditioner operates: cooling, heating or fan.  

3. 

Once the temperature is set in auto mode it is not possible to amend it.  It the desired temperature 
requires changing, change the unit out of Auto mode before changing it back. 

4. 

The unit will operate in the auto selected mode until set temperature is reached than switches the 
compressor off. Mode is locked until reset via mode button.  

5. 

You can use the FAN button to set the fan speed while in Auto mode. 

6. 

All indoor units must be operating in the same mode, otherwise a mode mismatch error will show.  
 

SLEEP MODE  

During sleep mode the unit will operate with a low fan speed to minimise the operational noise of the unit. 

1.  Press the 

SLEEP

 button  

2.  Set the desired temperature. 
3.  Press the 

SLEEP

 button; 

SLEEP

 indicator will appear on the display. Cancel the sleep mode by 

pressing this button again.  
 

CLEAN (Not available on all models) 

When pressed while the unit is in standby mode, the unit will power on in high speed fan mode, and run 
through the cleaning mode, before returning to standby mode. 

 

 

 

Summary of Contents for eiQ-3MS9K9K9K

Page 1: ...er and Installation Manual eiQ 3MS9K9K9K Thank you for choosing ElectrIQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page...

Page 2: ...it is confirmed ensure that all the boxes required have been received in good condition and the codes on each box matches your model on the table below Model Outdoor Indoor Pipekit QTY QTY QTY eiQ 3MS...

Page 3: ...they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Do not leave children unsupervised with this appliance Do not clean the uni...

Page 4: ...which is led to the evaporator 1 within the indoor unit The liquid expands into a gas at a low temperature and low pressure is converted This gas absorbs the warmth from the air in the room the coole...

Page 5: ...ton will also turn off the air conditioner TEMPERATURE The desired temperature is set using the up and down buttons within the range of 16 C 32 C This button turns on and off the horizontal swing func...

Page 6: ...ing mode AUTO MODE 1 Repeatedly press the MODE button until the AUTO indicator appears Set the desired temperature under auto mode to the required level between 16 32 C 2 The difference between the se...

Page 7: ...w fan speed to minimise the operational noise IMPORTANT AUTO RESTART The air conditioner will automatically restart when electricity is restored after a power cut If in doubt check the settings RANGE...

Page 8: ...ay a liquid in or over the appliance Exterior unit While the unit is disconnected from power Remove dirt and keep the air intake and exhaust openings free of debris etc Cleaning with chemicals may cau...

Page 9: ...e label Please read this installation manual completely before installing the product When the power cord is damaged replacement work shall be performed by authorized personnel only Installation work...

Page 10: ...hat the outdoor unit installation is made in respect to installation dimension diagram with easy maintenance access Select a place where it is out of reach of children Do not block utilities access or...

Page 11: ...rewdrivers Core hole cutter Number 14 7mm Masonry drill bit 1 5 inch number 10 screws Roundhead slotted 7mm Wall plugs Pipe cable detector Hammer Tape measure Spirit level Pencil and chalk Small Step...

Page 12: ...12 Also the following 2 inch Pipe clips Circuit breaker when drilling inside and out Garden gloves when lifting the outdoor unit Dustsheets Foam Filler Silicone sealant and gun...

Page 13: ...13...

Page 14: ...t then the rubber bung on the right side needs to be moved to the left outlet to avoid leakage The outlet of the water tray needs adjusting down so the water follows the gravity fall If the drains is...

Page 15: ...ed to be 200 cm 2 Either the indoor unit or the outdoor unit can be higher but the height difference must comply with a max 5 metres level difference 3 Try to avoid the bending of the pipes as much as...

Page 16: ...pe between the indoor and outdoor and tighten the connecting nut by hand to prevent cross threading Secure them with a wrench applying the maximum torque as shown in the table above 3 Pressure test an...

Page 17: ...e to carefully check if there is any leakage at the joints This is an important step to ensure the quality of installation Once a leak is detected proper action should be taken immediately 1 For good...

Page 18: ...gerant flow reducing performance or preventing operation Please use a twisting wheel to avoid improper bending Over bent soft pipes will lead to irregular bending Please use a rigid elbow to maintain...

Page 19: ...national wiring regulations If the supply cord is damaged it must be replaced by the manufacturer its service agent or a suitably qualified person in order to avoid a hazard The unit is designed to b...

Page 20: ...plit air conditioning system E9 Outdoor module fault Malfunction of outdoor module F5 Outdoor ambient temperature sensor fault Open circuit or short circuit of outdoor temp sensor F6 Outdoor coil temp...

Page 21: ...uit of outdoor coil temperature sensor E7 T4 temperature sensor fault Short circuit or open circuit of outdoor ambient temperature sensor E8 Exhaust temperature sensor fault Short circuit or open circ...

Page 22: ...Annual Consumption KW 377 2205 Compressor Model ATL232SDNC9AUY Type Rotary Piston scroll Rotary Brand Highly Capacity W 6535 Power input A 2075 RLA A 10 7 Refrigerant oil 68HES H or equivalent 880 20m...

Page 23: ...ed or replaced Faults arising from a faulty installation are specifically excluded The system must be serviced annually by qualified personnel This unit must be operated under conditions as recommende...

Page 24: ...e check the troubleshooting guide before calling the service line If the unit still fails to operate call 0871 620 1057 or complete the online form Office hours 9AM 5PM Monday to Friday www ElectrIQ c...

Reviews: