1. Drill a piping hole (90mm) through the external wall at a slight downwards angle
2. Insert the piping sleeve in to the hole to prevent damage to the connecting copper pipes and
wiring when they are passed through the opening.
1. Always install the rear bracket horizontally. The pipes in the unit can be installed to the left (default) or can
be changes to exit on the right side. If the drain pipe needs to be changed from left to right then the rubber
bung on the right side needs to be moved to the left outlet to avoid leakage. The outlet of the water tray needs
adjusting down so the water follows the gravity fall. If the drains is running against gravity at any stage, goes
above the tray level or the run is longer than 5 meters, an inline water pump must be used.
2. Fix the rear bracket to the wall using screws and suitable wall plugs.
3. Be sure to use the correct screws and fixings for the type of wall where the bracket is installed, and that the
mounted bracket can withstand at least 60 kgs of weight. The weight should be equally distributed between
each screw.