ELECTRICAL CONNECTION OF THE AIR CONDITIONER
The electrical connections can be found under the protective plastic cover. Remove this from
the side of the outdoor unit to gain access to the electrical connections.
Connect the indoor power and control wires with the matching outdoor wire as per the electrical
diagram.
Do not attempt to connect the wires in a different way to the diagram on the air conditioner as
this could damage the unit and invalidate the warranty.
Secure the wires and replace the cover before operating the unit.
The appliance should be installed in accordance with national wiring regulations.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a
suitably qualified person in order to avoid a hazard.
The unit is designed to be hard wired and a suitable switch with a contact separation of at least
3mm in all poles must be added to the fixed wiring.
Note: in some models you may connect the indoor wire connector with an optional outdoor
defrost probe The air conditioner electrical wiring must follow the specific country regulations. If
power cord is damaged must be replace by a qualified electrician.
There are only three thread buckles on the electric box connection plate,
o
The left one is for the power line.
o
The middle one is for the cables for both Unit-A and Unit-B.
o
The right one is be used for Unit-
C’.