ElectrIQ ECD70 User Manual Download Page 9

 

OPERATION 

NOTES: 

 

The

 

recommended humidity for a standard room is within the range of 50% to 70%, provided no 

special requirements are made.  

 

Although the desired humidity can be set as low as 10%, lower settings will act as a continuous 
mode, as they are unlikely to be achievable in the UK. 

 

 

 

 

 

  

 

 

Press once to turn the unit on. Press again to turn the unit off. 

 

Increase the desired humidity between 10% and 95%RH. 
Also used to adjust the timer duration following pressing the TIMER button 

 

Decrease the desired humidity between 10% and 95%RH. 
Also used to adjust the timer duration following pressing the TIMER button 

 

Press the timer button to activate the timer. Use the UP and DOWN buttons to 
adjust the timer duration (00-24hr). 
The timer can be used in standby mode to specify in how many hours the unit 
will turn on, or while the unit is operating to specify in how many hours the unit 
will turn off. The Timer indicator will illuminate when the timer is activated.

 

 

The uplift pump works by collecting water within a small tank, before using a 
small pump to expel the water from the machine through the drain pipe. When 
the tank is operating, the pump light will illuminate. 

 

Power 

Button 

Timer 

Button 

Decrease 

Button 

Increase 

Button 

Pump 

Indicator 

Timer 

Indicator 

Power 

Indicator 

Display 

Summary of Contents for ECD70

Page 1: ...ER ECD70 70 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier Please keep it safe for future reference Visit our page www electriQ c...

Page 2: ...TS 5 FEATURES 6 PRODUCT OVERVIEW 6 POSITIONING THE DEHUMIDIFIER 7 ASSEMBLY 8 OPERATION 9 CONTINUOUS DRAINAGE 10 CARE AND MAINTENANCE 11 TROUBLESHOOTING 12 FREQUENTLY ASKED QUESTIONS 13 TECHNICAL SPECI...

Page 3: ...it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate t...

Page 4: ...ensure all hazards are minimized The refrigerant system should not be perforated or punctured Do not place the unit next to heat sources e g electrical fires fireplaces etc Avoid mishandling the dehu...

Page 5: ...AFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER PARTS Bolts For Axel x 4 Bolts For Handle x 4 6m Flexible Water Pipe x 1 Pre attached to the unit Nuts For Wheels x 2 Washers For Wheels x 2 W...

Page 6: ...tive humidity can be adjusted in increments of 5 between 40 and 95 ensuring your room is not dried too much and power is not wasted FEATURES Your dehumidifier belongs to the electriQ dehumidifier rang...

Page 7: ...r this reason the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home A warm hallway or landing is an excellent posit...

Page 8: ...e plugging in ATTACHING THE WHEELS 1 Attach the Axel to the base of the appliance using the 4 bolts provided 2 Fix the wheels onto each end of the axel using the supplied washers and nuts ensuring tha...

Page 9: ...ed to adjust the timer duration following pressing the TIMER button Press the timer button to activate the timer Use the UP and DOWN buttons to adjust the timer duration 00 24hr The timer can be used...

Page 10: ...the previously operating settings DEFROSTING MODE DESCRIPTION Automatic defrosting Sensor at normal state This mode is entered when the compressor runs constantly for 30 min and the coil temperature i...

Page 11: ...n position as shown in the diagram 5 Never use the unit without the antibacterial mesh dust filter CLEAN THE GRILLE AND CASE Use water and a mild detergent to clean the washable mesh filters Do not us...

Page 12: ...er manual Unit is noisy during operation Is the unit on an uneven surface Please place on flat horizontal surface Is filter clogged Please service the filters regularly as per user manual Unit leaking...

Page 13: ...A Drainage Pipe Internal Diameter 4mm Maximum uplift of condensate 5m Product Dimensions mm 460x870x545mm Weight Kgs 42 Refrigerant R290 280g Minimum room area M2 14 Global Warming Potential 3 Operati...

Page 14: ...old cycle there should be cold air coming out of the unit During the hot cycle hot dry air should be coming out of the outlet grill ENVIRONMENTAL PROTECTION Disposal Do not dispose this product as uns...

Reviews: