The  appliance  must  be  placed  in  a  room  without  sources  of  ignition  (for  example:  open 
flames, an operating gas appliance or an operating electric heater). 

 

R290 refrigerant gas complies with European environmental directives. 

 

R290 has a low GWP (Global Warming Potential) of 3. 

 

The unit contains about 280g of R290 refrigerant gas. 

 

Do not use or store the appliance in an unventilated space with an area smaller than shown 
in the specification table per unit.  

 

If the appliance is installed, used or stored in an unventilated room, the room must be such 
as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire 
or explosion should the refrigerant come into contact with electric heaters, stoves or other 
sources of ignition. 

 

Refrigerant gas may be odourless.  

 

Do not use the product and contact the retailer for advice, if damage has occurred to the unit 
which may have compromised the refrigerant system. 

 

Any  repairs  or  maintenance  must  only  be  carried  out  on  the  unit  by  a  suitably  qualified 
engineer.    Before  opening  and  servicing  the  unit  the  authorized  engineer  must  be  in 

possession  of  a  copy  of  the  manufacturer’s  service  manual  and  must  follow  the  safety 

information contained within it to ensure all hazards are minimized. 

 

The refrigerant system should not be perforated or punctured. 

 

Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.)  

 

Avoid  mishandling  the  dehumidifier. Dropping,  throwing  the  unit  can  cause  damage  to  its 
internals and increases the risks of operating it.  

 

Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or liquids in 
the vicinity of this dehumidifier or any other appliance.  

 

This dehumidifier must not be used in spaces where there is a high concentration of gases, 
solvent or other volatile organic compounds; in very dusty environments; in any domestic, 
commercial or industrial environment where the air composition is flammable.  

  

ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS  

 

 

Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow 
troubleshoot procedure if the self-opening louvers do not open on power on.   

 

For maximum performance the minimum distance from a wall or objects should be 20 cm  

 

Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should only 
need cleaning once every three weeks (approximately).   

 

Since  the  filters  remove  airborne  particles,  more  frequent  cleaning  maybe  necessary, 
depending on the air quality. Vacuum both mesh and optional carbon filters and wash the 
mesh filters with hot soapy water and dry them before placing them back in the unit.  

 

 

 

Summary of Contents for ECD70

Page 1: ...ER ECD70 70 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier Please keep it safe for future reference Visit our page www electriQ c...

Page 2: ...TS 5 FEATURES 6 PRODUCT OVERVIEW 6 POSITIONING THE DEHUMIDIFIER 7 ASSEMBLY 8 OPERATION 9 CONTINUOUS DRAINAGE 10 CARE AND MAINTENANCE 11 TROUBLESHOOTING 12 FREQUENTLY ASKED QUESTIONS 13 TECHNICAL SPECI...

Page 3: ...it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate t...

Page 4: ...ensure all hazards are minimized The refrigerant system should not be perforated or punctured Do not place the unit next to heat sources e g electrical fires fireplaces etc Avoid mishandling the dehu...

Page 5: ...AFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER PARTS Bolts For Axel x 4 Bolts For Handle x 4 6m Flexible Water Pipe x 1 Pre attached to the unit Nuts For Wheels x 2 Washers For Wheels x 2 W...

Page 6: ...tive humidity can be adjusted in increments of 5 between 40 and 95 ensuring your room is not dried too much and power is not wasted FEATURES Your dehumidifier belongs to the electriQ dehumidifier rang...

Page 7: ...r this reason the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home A warm hallway or landing is an excellent posit...

Page 8: ...e plugging in ATTACHING THE WHEELS 1 Attach the Axel to the base of the appliance using the 4 bolts provided 2 Fix the wheels onto each end of the axel using the supplied washers and nuts ensuring tha...

Page 9: ...ed to adjust the timer duration following pressing the TIMER button Press the timer button to activate the timer Use the UP and DOWN buttons to adjust the timer duration 00 24hr The timer can be used...

Page 10: ...the previously operating settings DEFROSTING MODE DESCRIPTION Automatic defrosting Sensor at normal state This mode is entered when the compressor runs constantly for 30 min and the coil temperature i...

Page 11: ...n position as shown in the diagram 5 Never use the unit without the antibacterial mesh dust filter CLEAN THE GRILLE AND CASE Use water and a mild detergent to clean the washable mesh filters Do not us...

Page 12: ...er manual Unit is noisy during operation Is the unit on an uneven surface Please place on flat horizontal surface Is filter clogged Please service the filters regularly as per user manual Unit leaking...

Page 13: ...A Drainage Pipe Internal Diameter 4mm Maximum uplift of condensate 5m Product Dimensions mm 460x870x545mm Weight Kgs 42 Refrigerant R290 280g Minimum room area M2 14 Global Warming Potential 3 Operati...

Page 14: ...old cycle there should be cold air coming out of the unit During the hot cycle hot dry air should be coming out of the outlet grill ENVIRONMENTAL PROTECTION Disposal Do not dispose this product as uns...