CONTINUOUS DRAINAGE
The ECD70 does not include a removeable tank, and instead includes an internal uplift pump to extract the
water collected. A 6 metre drainage pipe is provided attached on the side of the unit. If this needs to be
extended, we advise to fit it into a pipe with a larger diameter, and ensure the larger pipe is travelling
downwards. The uplift pump collects water, and then when a sufficient amount is collected it will be
automatically pumped out of the unit through the drain pipe. It can be used to raise the water by upto 5
meters to drain to a sink or drain. Please note this is the maximum height, and will be affected both by the
diameter of the pipe used, and the total length of the drain pipe.
To ensure effective performance of the pump, it is advised that the pipe is routed so that the upwards
section is close to the unit. After the upwards section of the pipe, it should have a gentle downwards slope
to prevent backflow to the pump, and aid drainage.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost
mode. Following completion of the defrost mode, the unit will return to the previously operating settings.
DEFROSTING MODE
DESCRIPTION
Automatic defrosting
Sensor at normal state
This mode is entered when the
compressor runs constantly for 30
min and the coil temperature is
≦
-1
℃
.
In defrost mode the compressor stops
running, the fan continues running
and the defrosting light is on.
Timing defrosting
The unit defrosts for 8 minutes
Note: When the ambient temperature is low, the appliance will enter defrost mode more often
HUMIDITY CONTROL
When the unit reaches the desired humidity set, both the fan and compressor will shut down; and when
the humidity of the room is above the desired level both fan and compressor will operate.
If the room humidity displayed appears to be incorrect, it can be adjusted by following the below:
1.
In standby mode, press and hold the TIMER Button for over 10 seconds.
2.
Both the Set Humidity and Current Humidity symbol will flicker and the humidity display will show
the current humidity
3.
Use the UP and DOWN buttons to adjust the humidity reading.
FAULT PROTECTION
The intelligent logic within the unit will monitor the performance of the refrigerant circuit. If after 10
minutes the temperature of the cold coil within the unit has not reduced sufficiently, the unit will enter
standby mode and
“PRESSURE
HOLDING”
will be displayed on the control panel. The unit will not operate
until the fault has being rectified.