ElectrIQ CDW12L User Manual Download Page 10

Care and Maintenance 

Always  shut  off  the  unit  and  unplug  from  the  mains  before  cleaning  or 
performing  any  maintenance.  When  it  is  not  in  use  for  long  periods  it  is 
advisable  to  remove  the  plug  from  the  power  socket.  Do  not  use  chemical 
solvents  (such  as  benzene,  alcohol  or  gasoline)  as  they may  cause  irreversible 
damage to the unit.   
 

1. Clean the Grille and Case 

Use  water  and  a  mild  detergent.  Do  not  use  bleach  or 

abrasives.  Do  not  splash  water  directly  onto  the  main  unit. 

Doing  so  may  cause  an  electrical  shock  and  can  lead  to  the 
insulation  to  deteriorate,  or  cause  the  unit  to  rust.  The  air 

intake  and  outlet  grilles  get  soiled  easily,  so  use  a  vacuum 
attachment  or  soft  brush  to  clean.  If  the  mesh  filter  is  dirty 

hoover  it,  if  it  is  heavily  soiled  wash  it  with  warm  soapy water 

and dry thoroughly before reinserting it in the unit. 
 

 
 

 
 

   

2. Clean the water tank 

Every  few  weeks,  clean  the  tank  to  prevent  growth  of  mould,  mildew  and  bacteria. 
Partially fill the tank with clean water and add a little mild detergent. Swish it around in 
than empty the tank and rinse. 
NOTE:  Do  not  use  a  dishwasher  to  clean  the  tank.  After  cleaning  and  drying  the  tank 
must be reinserted securely into dehumidifier in order to restart operation 
 

Frequently Asked Questions 

Why doesn’t the dehumidifier seem to extract much water if the temperature is low? 

This is a compressor dehumidifier which works best in temperatures above 15⁰C. If the 
temperature is low and the air is dryer than the setting on the humidistat the unit will 
not  extract  water.  If  you  want  to  use  a  dehumidifier  for  outside  buildings,  unheated 
properties, boats or garages please check our desiccant range. 

Why doesn’t the unit work /or stops suddenly? 

The water tank may be full or displaced. To rectify: empty the tank and carefully place 
the tank back in the unit. 
Also  the  unit  may  be  running  in  dehumidifying  mode  with  a  low  room  temperature. 
Please check if the room temperature is lower than 5⁰C. If so, the unit will stop working 
while in dehumidifying mode. (unit may be defrosting). 
The ambient operating range is between 5⁰C and 35⁰C with a relative humidity ranging 
from 30% to 80%. For maximum efficiency use the unit between 15⁰C and 32⁰C. 

8

All manuals and user guides at all-guides.com

Summary of Contents for CDW12L

Page 1: ...UAL Thank you for choosing ElectrIQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www electrIQ co uk for our entire range...

Page 2: ...0 Troubleshooting 9 Water Drainage 7 Care and Maintenance 8 Positioning 6 Quick reference guide 4 Contents Safety Instructions 1 Installation 2 Parts and Control Panel 3 All manuals and user guides at...

Page 3: ...spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never...

Page 4: ...dry them before placing them back in the unit Installation Remove any water from the water tank before starting the unit In order to save energy do not open windows or doors while the unit is running...

Page 5: ...Dry Air Outlet 3 Carrying Handle 4 Control Panel 5 Mesh Filter 6 Air Intake 7 Water tank 8 Supply cord OPTIONAL 1 Activated carbon filter Optional 2 PU filter Optional 1 2 3 All manuals and user guid...

Page 6: ...eed settings Key Low High Humidity Level Timer 2 digit display The led indicator performs the following functions 1 When the unit is plugged in it will indicate the room humidity level 2 When the humi...

Page 7: ...icators Tank Full Light Red light will be on and the unit will beep when the tank is ready to be emptied or when the tank is removed or not replaced in the proper position The water level control swit...

Page 8: ...ions codes Positioning the dehumidifier A badly positioned dehumidifier will have little effect in effectively drying the place In positioning the dehumidifier please ensure circulation of air in not...

Page 9: ...e way into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove the float from the water tank The water full sensor...

Page 10: ...t around in than empty the tank and rinse NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be reinserted securely into dehumidifier in order to restart operation...

Page 11: ...ck float and make sure tank is properly inserted in unit Dehumidifier does not extract water Is the unit set to a humidity level lower than the one in the room Set the humidity level on the humidistat...

Page 12: ...z Dehumidifying capacity 12 L day at 30 C 80 RH Rated Power 240 W 1 5 Amp Starting current 7 Amp Tank Capacity 1 5 litres Humidity settings range 40 80 Refrigerant R134 100 grams Airflow m3 h 140 Nois...

Page 13: ...ntact the local council for details of your local household waste recycling centres ElectrIQ UK SUPPORT www ElectrIQ co uk support Please for your own convenience make these simple checks before calli...

Reviews: