PERFORMANCE DATA
JKD DCI 19 Version - 1
5.2 ELSI-JKD012-N11 / ELAU-VKD012-H11
1) Cooling
ID COIL ENTERING AIR DB/WB TEMPERATURE [C
0
]
OD COIL ENTERING
AIR DB
TEMPERATURE [C
0
]
DATA
22/15
24/17
27/19
29/21
32/23
-10 - 20
(protection range)
TC
80 - 110 % of nominal
SC
80 - 105 % of nominal
PI
25 - 50 % of nominal
25
TC
3.42
3.65
3.87
4.09
4.32
SC
2.61
2.67
2.72
2.77
2.83
PI
0.86
0.88
0.89
0.91
0.93
30
TC
3.26
3.48
3.70
3.93
4.15
SC
2.55
2.60
2.65
2.71
2.76
PI
0.96
0.98
0.99
1.01
1.03
35
TC
3.09
3.32
3.54
3.76
3.99
SC
2.48
2.53
2.59
2.64
2.69
PI
1.06
1.08
1.10
1.11
1.13
40
TC
2.93
3.15
3.38
3.60
3.82
SC
2.42
2.47
2.52
2.58
2.63
PI
1.16
1.18
1.20
1.21
1.23
46
TC
2.73
2.95
3.18
3.40
3.63
SC
2.34
2.39
2.44
2.50
2.55
PI
1.28
1.30
1.32
1.33
1.35
Legend:
TC - Total Cooling Capacity [kW]
SC - Sensible Capacity [kW]
PI - Power Input [kW]
WB - Wet Bulb Temperature
DB - Dry Bulb Temperature
ID - Indoor
OD - Outdoor
Summary of Contents for ELAU-VKD009-H11
Page 12: ...DIMENSIONS Version 1 12 JKD DCI For ELSI JKD009 N11 For ELSI JKD012 N11...
Page 13: ...DIMENSION JKD DCI 13 Version 1 For ELSI JKD018 N11 For ELSI JKD024 N11...
Page 16: ...DIMENSIONS Version 1 16 JKD DCI...
Page 28: ...WIRING DIAGRAM Version 1 28 JKD DCI 7 3 Outdoor unit ELAU VKD018 H11...
Page 29: ...WIRING DIAGRAM JKD DCI 29 Version 1 7 4 Outdoor unit ELAU VKD024 H11...
Page 66: ...EXPLODED VIEW AND SPARE PART LIST Version 1 66 JKD DCI 12 2 ELSI JKD012 N11...
Page 68: ...EXPLODED VIEW AND SPARE PART LIST Version 1 68 JKD DCI 12 3 ELSI JKD018 N11...
Page 70: ...EXPLODED VIEW AND SPARE PART LIST Version 1 70 JKD DCI 12 4 ELSI JKD024 N11...
Page 72: ...EXPLODED VIEW AND SPARE PART LIST Version 1 72 JKD DCI 12 5 ELAU VKD009 H11...
Page 74: ...EXPLODED VIEW AND SPARE PART LIST Version 1 74 JKD DCI 12 6 ELAU VKD012 H11...
Page 76: ...EXPLODED VIEW AND SPARE PART LIST Version 1 76 JKD DCI 12 7 ELAU VKD018 H11...
Page 78: ...EXPLODED VIEW AND SPARE PART LIST Version 1 78 JKD DCI 12 8 ELAU VKD024 H11...
Page 80: ...SERVICE MANUAL JKD DCI Series...