RATING CONDITIONS
3.
RATING CONDITIONS
ATING CONDITIONS
Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
Cooling:
Cooling:
Indoor: 27
o
C DB 19
o
C WB
Indoor: 27
o
C DB 19
o
C WB
Outdoor: 35
o
C DB
Outdoor: 35
o
C DB
Heating:
Heating:
Indoor: 20
o
C DB
Indoor: 20
o
C DB
Outdoor: 7
o
C DB 6
o
C WB
Outdoor: 7
o
C DB 6
o
C WB
Operating
Limits
Operating
Limits
R410A
R410A
Indoor Outdoor
Upper limit
32
o
C DB 23
o
C WB 43
o
C DB
Cooling
Lower limit
21
o
C DB 15
o
C WB -5
o
C DB
Upper limit
27
o
C DB
24
o
C DB 18
o
C WB
Heating
Lower limit
10
o
C DB
-15
o
C DB RH80%
Voltage
1-PH 50Hz 195 – 265 V
Service Manual – VBZ DCI 1-A.1 GB
3-1
Summary of Contents for ELAU-VBZ214-H11
Page 16: ...OUTLINE DIMENSION 4 2 Service Manual VBZ DCI 1 A 1 GB 4 2 Indoor JYD018...
Page 17: ...OUTLINE DIMENSION 4 3 Outdoor VBZ214 Service Manual VBZ DCI 1 A 1 GB 4 3...
Page 18: ...OUTLINE DIMENSION 4 4 Service Manual VBZ DCI 1 A 1 GB 4 4 Outdoor VBZ318 VBZ430...
Page 35: ...WIRING DIAGRAM 9 2 Service Manual VBZ DCI 1 A 1 GB 9 3 YAZ214...
Page 36: ...WIRING DIAGRAM 9 4 YAZ318 Service Manual VBZ DCI 1 A 1 GB 9 3...
Page 37: ...WIRING DIAGRAM 9 4 Service Manual VBZ DCI 1 A 1 GB 9 5 YAZ430...
Page 38: ...WIRING DIAGRAM 9 6 Wiring connection between IDU and ODU Service Manual VBZ DCI 1 A 1 GB 9 5...
Page 39: ...WIRING DIAGRAM 10 REFRIGERATION DIAGRAMS Service Manual VBZ DCI 1 A 1 GB 10 1...
Page 73: ...EXPLODED VIEW SPARE PART LIST 15 12 Service Manual VBZ DCI 1 A 1 GB APPENDIX...