2-6
PRODUCT DATA SHEET
Revision Y05-02
Service Manual - DUO Series
Model Indoor Unit
ALPHA 12*12
Model Outdoor Unit
OU7-1212
Installation Method
Wall Mounted
Characteristics Units
Cooling
Heating
Btu/hr 23884
25000
Capacity
(1)
kW 7
7.35
Power Input
(1)
kW
2.5
2.50
COP
(1)
W/W
2.8
2.94
Energy Efficiency Class
Power Supply
V/Ph/Hz
230/1/50+/-10%
Rated Current
A
Starting Current
A
48
Circuit Breaker Rating
A
Fan Type & Quantity
Crossflow*1
Fan Speed
H/M/L
RPM
Airflow
(2)
H/M/L
m
3
/hr 600+600
450+450
External Static Pressure
Min-Max
Pa
N/A
Sound Power Level
(3)
H/M/L
dB
(A)
54+54
47+47
Sound Pressure Level
(4)
H/M/L
dB
(A)
42+42
36+36
Moisture Removal
L/hr
1.3+1.3
Condensate Drain Tube I.D.
mm
16
Dimensions W/H/D
mm
840*250*180
Weight kg
8+8
Package Dimensions
W/H/D
mm
930*325*265
Packaged Weight
kg
N/A
Units per Pallet
Units
36
R
O
O
D
NI
Stacking Height
Units
9
Refrigerant Control
Capillary
Compressor Type, Model
Rotary
Fan Type & Quantity
Axial*1
Fan Speeds
H/L
RPM
850
Airflow H/L
m
3
/hr 3100
3100
Sound Power Level
H/L
dB (A)
66.8
Sound Pressure Level
(4)
H/L
dB
(A)
59
Dimensions W/H/D
mm
900*680*340
Weight kg
74
Package Dimensions
W/H/D
mm
985*730*406
Packaged Weight
kg
76
Units per Pallet
Units
6
Stacking Height
Units
2
Refrigerant Type
R410A
Refrigerant Charge
GR
880+880
Liquid Line
In
2*6.35(1/4")
Suction Line
In
2*9.53(3/8")
Max. Tubing Length
m
15
R
O
O
D
T
U
O
Connections
Between Units
Max. Height Difference
m
7
Operation Control Type
LCD REMOTE CONTROL
Heating Elements
kW
Others
1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
2.1.5
ALPHA 12+12 / OU7-1212
3
3
16
24 / 24