2-1
PRODUCT DATA SHEET
Revision Y05-02
Service Manual - DUO Series
2. PRODUCT
DATA
SHEET
Model Indoor Unit
WNG 9+9
Model Outdoor Unit
OU7-0909
Installation Method
Wall Mounted
Characteristics Units
Cooling
Heating
Btu/hr 19520
18315
Capacity
(1)
kW 5.72
5.37
Power Input
(1)
kW
1.78
1.67
COP
(1)
W/W
3.2
3.2
Power Supply
V/Ph/Hz
230/1/50+/-10%
Rated Current
A
7.7
7.3
Starting Current
A
37.4
Circuit Breaker Rating
A
16
Fan Type & Quantity
Crossflow*1
Airflow
(2)
H/M/L
m
3
/hr 450
380
330
External Static Pressure
Min-Max
Pa
N/A
Sound Power Level
(3)
H/M/L
dB
(A)
44
46
49
Sound Pressure Level
(4)
H/M/L
dB
(A)
28
31
35
Moisture Removal
L/hr
2*0.9
Condensate Drain Tube I.D.
mm
16
Dimensions W/H/D
mm
810*190*285
Weight kg
11
Package Dimensions
W/H/D
mm
945*395*655
Units per Pallet
Units
32
R
O
O
D
NI
Stacking Height
Units
8
Refrigerant Control
Capillary tube
Compressor Type, Model
Rotary
Fan Type & Quantity
Axial*1
Fan Speeds
H/L
RPM
850
Airflow H/L
m
3
/hr 3100
Sound Power Level
H/L
dB (A)
66.8
Sound Pressure Level
(4)
H/L
dB
(A)
59
Dimensions W/H/D
mm
900*680*340
Weight kg
72
Package Dimensions
W/H/D
mm
985*730*406
Packaged Weight
kg
74
Units per Pallet
Units
6
Stacking Height
Units
2
Refrigerant Type
R410A
Refrigerant Charge ST/ RC outdoor
gr
750+750 / 730+730
Liquid Line
In
2*6.35(1/4")
Suction Line
In
2*9.53(3/8")
Max. Tubing Length
m
15
R
O
O
D
T
U
O
Connections
Between Units
Max. Height Difference
m 7
Operation Control Type
LC D REMOTE CONTROL
Heating Elements
kW
NO
Others
1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
2.1
WNG 9+9 / OU7- 0909
18.7 / 18.7