background image

GB

 

PIR

 

Motion

 

Sensor

 

(IRA

­

8)

 

The

 

PIR

 

picks

 

up

 

movements

 

within

 

an

 

assigned

 

area

 

and

 

signals

 

the

 

Control

 

Panel

 

to

 

activate

 

the

 

alarm

 

if

 

an

 

intruder

 

crosses

 

its’

 

path

 

of

 

detection.

 

The

 

PIR

 

consists

 

of

 

a

 

two

part

 

design

 

made

 

up

 

of

 

a

 

cover

 

and

 

a

 

base.

   

The

 

cover

 

contains

 

all

 

the

 

electronics

 

and

 

optics

 

and

 

the

 

base

 

provides

 

a

 

means

 

of

 

fixing.

 

The

 

base

 

has

 

knockouts

 

to

 

allow

 

mounting

 

on

 

either

 

a

 

flat

 

surface

 

or

 

in

 

a

 

corner

 

situation

 

with

 

fixing

 

screws

 

and

 

plugs

 

provided.

 

Provision

 

for

 

a

 

tamper

 

switch

 

that

 

will

 

be

 

activated

 

when

 

the

 

cover

 

is

 

detached

 

from

 

the

 

base

 

prevents

 

unauthorized

 

access

 

and

 

removal

 

from

 

the

 

mounting

 

surface.

   

The

 

PIR

 

can

 

also

 

alert

 

you

 

to

 

signal

 

communication

 

problems

 

and

 

low

 

battery

 

situations.

 

Inside

 

The

 

PIR

 

is

 

designed

 

to

 

give

 

a

 

typical

 

detection

 

range

 

of

 

12

 

meters

 

when

 

mounted

 

at

 

2

 

meters

 

above

 

ground.

 

Identifying

 

the

 

parts.

 

Remove

 

the

 

cover

 

by

 

loosening

 

the

 

button

 

fixing

 

screw,

 

the

 

inside

 

of

 

the

 

PIR

 

will

 

revealed

 

as

 

shown.

 

Learn/Test

 

Button

 

This

 

button

 

is

 

used

 

for

 

testing

 

the

 

radio

 

performance

 

and

 

for

 

learning

 

purpose.

 

Tamper

 

Switch

 

The

 

Tamper

 

switch

 

protects

 

the

 

enclosure

 

from

 

being

 

opened.

 

Test/Normal

 

Mode

 

Jumper

 

Switch

 

(JP1)

 

It

 

is

 

a

 

3

pin

 

jumper

 

switch

 

Back

 

If

 

the

 

jumper

 

link

 

is

 

in

 

inserted

 

between

 

the

 

left

 

2

 

pins,

 

the

 

PIR

 

is

 

in

 

Test

 

mode.

 

 

If

 

the

 

jumper

 

link

 

is

 

inserted

 

between

 

the

 

right

 

2

 

pins,

 

the

 

PIR

 

is

 

in

 

Normal

 

operation

 

mode.

 

 

 
 

Supervision

 

Function

 

(JP2)

 

If

 

the

 

jumper

 

link

 

is

 

in

 

inserted

 

between

 

the

 

left

 

2

 

pins,

 

the

 

PIR

 

operates

 

in

 

supervision

mode

 

and

 

conducts

 

a

 

periodic

 

selftest.

 

If

 

the

 

jumper

 

link

 

is

 

inserted

 

between

 

the

 

right

 

2

 

pins,

 

the

 

PIR

 

is

 

in

 

Normal

 

operation

 

mode.

 

If

 

the

 

Control

 

Panel

 

can’t

 

receive

 

the

 

Supervisory

 

signals

 

transmitted

 

from

 

a

 

certain

 

PIR,

 

an

 

Out

Of

Orde

r”

 

fault

 

message

 

will

 

be

 

generated.

   

Sleep

 

Timer

 

The

 

PIR

 

has

 

a

 

sleep

 

time

 

of

 

approximately

 

1

 

minute

 

to

 

conserve

 

power.

   

After

 

transmitting

 

a

 

detected

 

movement,

 

the

 

PIR

 

will

 

not

 

retransmit

 

for

 

1

 

minute;

 

any

 

further

 

movement

 

detected

 

during

 

this

 

sleep

 

period

 

will

 

extend

 

the

 

sleep

 

time

 

by

 

another

 

minute.

 

In

 

this

 

way

 

continuous

 

movement

 

in

 

front

 

of

 

a

 

PIR

 

will

 

not

 

unduly

 

exhaust

 

the

 

battery.

 

Test

 

mode

 

The

 

PIR

 

can

 

be

 

put

 

into

 

Test

 

mode

 

by

 

inserting

 

the

 

jumper

 

link

 

between

 

the

 

left

 

two

 

pins

 

of

 

the

 

Test

 

mode

 

jumper

 

switch.

 

In

 

Test

 

mode,

 

it

 

will

 

disable

 

the

 

sleep

 

timer

 

and

 

will

 

enable

 

the

 

LED

 

indicator

 

to

 

flash

 

every

 

time

 

a

 

movement

 

is

 

detected.

 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

z

 

The

 

jumper

 

must

 

not

 

be

 

left

 

in

 

this

 

position

 

in

 

normal

 

use;

 

otherwise

 

battery

 

life

 

will

 

be

 

shortened

 

and

 

the

 

local

 

low

 

battery

 

display

 

will

 

not

 

be

 

able

 

to

 

be

 

seen.

 

LED

 

Indicator

 

There

 

is

 

a

 

LED

 

Indicator

 

behind

 

the

 

lens

 

on

 

the

 

right

 

upper

 

corner.

 

In

 

Normal

 

operation

 

mode,

 

the

 

LED

 

Indicator

 

will

 

not

 

light

 

except

 

in

 

the

 

following

 

situations:

 

z

 

When

 

the

 

PIR

 

is

 

in

 

low

 

battery

 

condition,

 

every

 

time

 

it

 

transmits

 

a

 

detected

 

movement,

 

the

 

LED

 

will

 

flash

 

for

 

about

 

2

 

seconds.

 

z

 

When

 

the

 

cover

 

is

 

opened

 

and

 

the

 

tamper

 

switch

 

is

 

violated,

 

the

 

LED

 

will

 

flash

 

for

 

2

 

sec.

 

to

 

indicate

 

it

 

is

 

transmitting

 

the

 

Tamper

 

signal.

 

z

 

When

 

the

 

Tamper

 

condition

 

persists,

 

every

 

time

 

it

 

transmits

 

a

 

detected

 

movement,

 

the

 

LED

 

will

 

flash.

 

However,

 

if

 

the

 

PIR

 

is

 

in

 

Test

 

mode,

 

the

 

LED

 

will

 

flash

 

every

 

time

 

a

 

movement

 

is

 

detected.

 

Battery

 

The

 

PIR

 

use

 

two

 

1.5V

 

AA

 

alkaline

 

batteries

 

as

 

its

 

power

 

source.

 

The

 

PIR

 

will

 

have

 

a

 

typical

 

battery

 

life

 

of

 

over

 

2

 

years

 

at

 

an

 

average

 

of

 

50

 

activations

 

a

 

day.

 

Low

 

battery

 

detection

 

operates

 

at

 

a

 

threshold

 

of

 

2.2V+/

10%

 

where

 

the

 

PIR

 

has

 

enough

 

reserve

 

energy

 

to

 

typically

 

operate

 

for

 

1

 

month

 

before

 

complete

 

exhaustion.

 

The

 

low

 

battery

 

signal

 

will

 

be

 

sent

 

to

 

the

 

Control

 

Panel

 

along

 

with

 

regular

 

signal

 

transmissions

 

for

 

the

 

Control

 

Panel

 

to

 

display

 

the

 

status

 

accordingly.

 

 

 

Summary of Contents for IRA-8

Page 1: ...IRA 8 OWNERS MANUAL A Ar rt t 3 36 6 2 28 87 72 2...

Page 2: ...ult message will be generated Sleep Timer The PIR has a sleep time of approximately 1 minute to conserve power After transmitting a detected movement the PIR will not retransmit for 1 minute any furth...

Page 3: ...nd if it is to be corner or surface mounted z Ensure the Test Normal mode jumper switch JP1 is in Test mode position by inserting the jumper link between the left two pins of the jumper switch This is...

Page 4: ...nde att visas p displayen Vilol ge IR sensor har ett vilol ge p ca 1 minut detta f r att spara p batterierna Om sensorn k nt av en r relse under denna period skickas inget larm till kontrollpanelen F...

Page 5: ...tiftbrytaren r inst lld p testl ge detta g rs genom att flytta stiftbrytaren l ngst till v nster Detta r till f r att koppla bort vilol gesfunktionen s att LED indikatorn blinkar varje g ng som en r r...

Page 6: ...t ja l hett t st tietoa ohjauspaneeliin muut havainnot 1 minuutin aikana ei aiheuta uudelleen l hett mist Jos tunnistin jatkaa liikkeen havaintoa lepoaika lis ntyy yhdell minuutilla T m n toiminnon ta...

Page 7: ...en alustaan z Varmista ett Testi Normaali tilan kytkin JP1 on testitilassa yhdist m ll vasemman puolen kaksi nastaa siltauskytkimell T ll in lepotilan ajastin kytkeytyy pois p lt ja LED valo aktivoitu...

Page 8: ...TECHNICAL DATA Power 2 x 1 5V AA alkaline batteries Battery Life 3 years Range 15m to 30m through walls and ceilings Frequency 868 MHz Dimensions 120mm L 74mm W 55mm H Art nr 36 2872...

Page 9: ...anta best mmelser som framg r av direktiv 1999 5 EG och RoHs 2002 95 EG Hereby Electia AB declares that the IRA 8 is in compliance with the essential requirements and other relevant provisions of Dire...

Reviews: