background image

Poolsmart Plus

Touchscreen Heating Controller

Installation & Operating Manual

Summary of Contents for Poolsmart Plus

Page 1: ...Poolsmart Plus Touchscreen Heating Controller Installation Operating Manual ...

Page 2: ... heating controller manufactured in England to the highest standards To ensure your new product will give years of trouble free service please carefully read the following instructions Incorrect installation will affect your warranty Do not discard this manual please retain for future reference Product Overview ...

Page 3: ... it is sited no more than 3 metres from the swimming pool filtration pipe work and upstream i e before the heating appliance 2 ENGLISH The rear face of the PoolSmart Plus has an upper key hole screw hook located at the rear of the enclosure and 2 lower screw holes which are accessed after removing the 4 screws retaining the lower access cover at the front ...

Page 4: ... and regulations In any event the work must be carried out by a qualified electrician who will provide a certificate of conformity upon completion of the work Undo the lower cover screws and remove the electrical access cover All electrical connections should be made into the relevant terminal block position according to the labelled positions Connection Explanation Terminal 1 Incoming Live 100 to...

Page 5: ...2 www elecro co uk ENGLISH Wiring Diagram 4 ...

Page 6: ... Controller Overview The Touchscreen digital controller has been pre programmed with all the necessary parameters to ensure reliable service operation Below is an overview indicating the controller button keys and graphical symbols ENGLISH ...

Page 7: ...stantly maintained at your required temperature When Priority of Heating is activated the Symbol will be displayed on the screen The controller will then monitor the pool water temperature and start both the pool circulation pump and heating process when necessary Operating Instructions On initial power up of the controller the digital display will be illuminated The heating device will only be sw...

Page 8: ...ferential When the pool water has reached the required temperature the heating device will switch off and will not switch back on until the water temperature has fallen 0 6 C below the require temperature Operating Modes There are five operating modes The required Modes are selected by touching the M button key each touch causes the mode to change to the next mode The display will indicate which m...

Page 9: ...re as if first entering that mode the display will reflect this LANGUAGE English French German Spanish and Russian UNITS temperature units centigrade or fahrenheit CLOCK set current time TIMER four time settings for switching the heating device On and Off PROBE CAL Temperature calibration adjustment MODBUS Set Baud rate address and parity for BMS connection FACTORY Access restricted EXIT Language ...

Page 10: ...www elecro co uk 1 ENGLISH Language Setup continued Touch the UP DOWN button keys until the desired language is displayed then touch the O K button key to select 9 ...

Page 11: ... show LANGUAGE touch the UP DOWN button keys again to display the next option which is UNITS touch the O K Button key to select the display will show UNITS and CENTIGRADE touch the UP DOWN button keys to change to FAHRENHEIT if required touch the O K Button key to select and save the display will then revert back to UNITS ...

Page 12: ...e next option which is CLOCK touch the O K Button key to select the display will show SET TIME and the current clock time touch the UP DOWN button keys to change the clock time touch the O K Button key when the time is correct to save Note The time can only be set in the 24 hour format ...

Page 13: ... time touch the O K Button key to save the required time the display will then show TIMER 2 repeat the same procedure for all four ON OFF timer settings select EXIT If any Timers are not required set the ON OFF times the same The timer mode allows you to set up 4 on and off time periods when you would like heating to take place These can be set to take advantage of off peak energy tariffs or to en...

Page 14: ... the temperature calibration adjustment touch the O K Button key to select the display will then revert back to show PROBE CAL ENGLISH Probe calibration is usually not required However should you need to make an adjustment take a temperature reading from the pool wa ter with an accurate thermometer then adjust as required Example Actual Water Temp PoolSmart Plus Reading Adjustment Required 28 30 2...

Page 15: ... Button key to select and SET BAUD 19200 Baud will be displayed touch the UP DOWN button keys for the other option SET BAUD 9600 Baud touch the O K Button key to select the required Baud rate Set Address Touch the UP button and MODBUS SET ADDRESS will be displayed touch the UP DOWN button keys to set the required address touch the O K button key the display will revert back to show MODBUS SET ADDR...

Page 16: ...RITY touch the UP button key and MODBUS EXIT will be displayed touch the OK button key to select EXIT and the display will show MODBUS Touch the UP button key and the display will show FACTORY touch again and EXIT will be displayed touch OK and the controller will exit the INSTALLATION mode and revert to NORMAL mode FACTORY Setup This category has restricted access ENGLISH Once configured the MODB...

Page 17: ... in Standby mode the controller will display the text STANDBY Clock time and the Standby button key as below When in this mode the internal clock continues to run but there is no other functionality apart from the Standby button key ENGLISH ENGLISH ...

Page 18: ... flow has been detected by the flow switch the controller display will be as shown below indicating the following information 1 Normal and Time 2 Actual water temperature 3 Required temperature 4 If the Flow switch does not detect sufficient flow the message NO FLOW will be shown on the Display ENGLISH 1 2 3 4 ...

Page 19: ...until the TIMER symbol is displayed see below ENGLISH ENGLISH In this mode the controller will only heat during a timed on period and when receiving sufficient flow If no or insufficient flow is being recieved no heating will take place When in a timed off period no heating will take place ...

Page 20: ...AMPLING and after a further two minutes the display will change back PRIORITY ENGLISH Once the Priority of Heating feature has been enabled the controller will take a water temperature sample every hour and the message SAMPLING will be displayed If the pool water temperature is below the required temperature the controller will send a signal to the heating device to come on until the required temp...

Page 21: ...p After one hour a new water temperature sample will be taken if the sampled water is at or above the required temperature no heating will take place and the controller will switch the circulation pump off then one hour later take a new temperature sample The sequence will continue to repeat until Priority of Heating is switched off In this mode the controller will heat whenever it is receiving fl...

Page 22: ...Possible Cause 3 The controller is in a timed off period Check if the controller has the TIMER symbol displayed if it does check your clock and time period settings explained in the set up section Possible Cause 4 The heat output has not been correctly connected to the control circuit of your heating device Check the wiring diagram for verification on how the controller should be con nected to the...

Page 23: ... is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more information please contact your local Civic office your household waste disposal service or the retailer where you purchased th...

Page 24: ...www elecro co uk 11 Gunnels Wood Park Stevenage Hertfordshire SG1 2BH United Kingdom t 44 0 1438 749 474 f 44 0 1438 361 329 e sales elecro co uk www elecro co uk Copyright 2017 Z INS PSPC 50 1 5 ...

Reviews: