www.elecro.co.uk
20
Priority of Heating and Timer Mode
To activate the ‘Priority’ and ‘Timer’ modes together touch the ‘M’
button key until both symbols & are displayed.
ENGL
IS
H
ENGL
IS
H
ENGL
IS
H
ENGL
IS
H
ENGL
IS
H
reached the controller will switch the heating appliance off, followed by
the filtration pump.
After one hour a new water temperature sample will be taken, if the
sampled water is at or above the required temperature no heating will
take place and the controller will switch the circulation pump off, then one
hour later take a new temperature sample.
The sequence will continue to repeat until ‘Priority of Heating’ is switched
off.
In this mode the controller will heat whenever it is receiving flow during
a timed on period and ‘Priority of Heating’ will take place whenever the
timer is ‘OFF’.