background image

 

Z-Wave IR Extender PAR01                                   

 

 

 

 
 
 
 
 
 
 
 
 
 
PAR01, is a Z-Wave plus compliant Z-Wave-to-IR Bridge to control split 
air conditioner by receiving Z-Wave command and translating to 
Infrared command. With its comprehensive built-In and cloud-stored IR 
database (library). PAR01 can control different 
brands and models of air conditioners worldwide. 
PAR01 is a security enabled Z-Wave plus device. A security Enabled 
Z-Wave Plus Controller must be used in order to fully utilize the 
product. 
PAR01 is a Z-Wave slave device, it depends on gateway to setup 
particular AC brand with correct IR code. Different gateway has 
different user interface for setup. 
 
This  product  can  be  included  and  operated  in  any  Z-Wave

TM

  network   

with other Z-Wave

TM

 certified devices from other manufacturers and/or   

other applications.    All non-battery operated nodes within the network 
will  act  as  repeaters  regardless  of  vendor  to  increase  reliability  of  the 
network.   
 
The device adopts the Z-Wave

TM

 500 series chip, when your Z-Wave

TM

 

network  system  is  all  made  by  Z-Wave

TM

  500  series  devices.  The 

network system will have the advantages as below. 

 
Adding to Z-Wave

TM

 Network

 

 
In  the  first  time,  activate  the  device  through  battery,  then  it  can  be 
added  into  the  Z-Wave

TM

  network.    First,  make  sure  the  primary 

controller  is  in  the  add  mode.  And  then  power  on  the  device.  The 
device  will  auto  start  the  NWI  (Network  Wide  Inclusion)  mode.  And  it 
should  be  added  in  5  seconds.  You  will  see  the  LED  light  ON  one 
second. 
 

Function 

Description

 

Add 

1.

 

Have Z-Wave

TM

 Controller entered add mode. 

2.

 

Press the add key in the casing three times 

3.

 

After add successful, the device will wake to 
receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

 

Remove 

1.

 

Have Z-Wave

TM

 Controller entered remove mode. 

2.

 

Press the add key in the casing three times 

3.

 

Hold down the central key, then press the top-right 
key three times within 1.5 seconds to enter the 
remove mode.Node ID has been excluded. 

 

Reset??

 

Notice: Use this procedure only in the event that 
the primary controller is lost or otherwise 
inoperable.

 

1.

 

Hold down the central key, then press the top-right 
key four times within 1.5 seconds and do not 
release the top-right key in the 4

th

 pressed, and the 

LED will light ON. 

Note: PSR03-C is reset by pressing panic key four 
times within 1.5 seconds and do not release the top-
right key in the 4

th

 pressed. 

2.

 

After 3 seconds the LED will turn OFF, after that 
within 2 seconds, release the keys. If successful, 
the LED will light ON one second. Otherwise, the 

Summary of Contents for PAR01

Page 1: ...ivate the device through battery then it can be added into the Z WaveTM network First make sure the primary controller is in the add mode And then power on the device The device will auto start the NW...

Page 2: ...eTM network Get Started Step 1 Apply Power to PAR01 Open the PAR01 Casing InstallCR123 batteries PAR01 will detect the first applied power source to decide what Z Wave device role it will be in after...

Page 3: ...a code that does not support Heat but Original air conditioner supports Heat Function please continue to try next code until the correct one is selected You can record down your Device Code for futur...

Page 4: ...mmended IR Learning Mapping Table Parameter Number 25 Parameter Value Storage Location Thermostat Command IR Setting Storage in Celsius Unit Storage in Fahrenheit Unit 0 OFF OFF 1 ON Resume ON Resume...

Page 5: ...D Display the mapping table with temperatures do not apply due to different type of IR Control Protocol However User may still use OFF ON RESUME DRY AUTO or FAN Key for Learning Because the POWER key...

Page 6: ...the exter nal IR emitter cable to control each air conditioner Control Air Default 0x01 Conditioner 33 0x21 Range 0 to 1 0x00 or 0x01 1 SWING 0 0x00 Swing OFF function 1 0x01 Swing Auto Default Tempe...

Page 7: ...ue is in Hexadecimal Numbering Format if the Gateway only support decimal numbering format please change it to decimal value accordingly Reset to Factory Default Press and Hold PROG button for 3 secon...

Page 8: ...flash the firmware update is succeeded Caution Do not running the OTA when the battery is running low Spec Power by Li 602025 battery Signal Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 00 MHz US...

Page 9: ...AIRWELL 276 670 598 433 432 AKAI 434 ALPIN 718 717 715 714 625 624 AMANA 836 AMCOR 716 668 665 664 663 662 AMERICOOL 430 AMVENT 811 46 APTON 513 839 525 524 523 522 521 520 519 517 516 515 514 508 67...

Page 10: ...345 344 343 33 31 543 357 354 DAITSU 788 DANTEX 841 797 DEER SHUANGLU 592 1047 DELCHI 40 DELONGHI 819 818 787 91 46 503 13 DEMIRDOKUM 42 186 DIAMANT 106 DIMSTAL 545 DOCTOR 846 771 756 722 DONGBAO 652...

Page 11: ...1061 835 830 655 417 1003 999 836 406 256 75 657 535 257 210 209 208 207 198 197 172 156 77 76 23 HAMILTON DIGITAL 186 HAWRIN 894 HERAN 807 40 429 56 421 869 868 867 866 851 850 565 562 550 55 HESSTA...

Page 12: ...2 231 230 229 228 193 70 37 1117 982 981 884 883 882 881 500 355 351 237 186 176 153 93 57 35 340 347 MITSUBISHI HEAVY INDUSTRIES 346 322 319 317 316 278 1095 1084 574 568 356 329 243 36 1174 837 547...

Page 13: ...UI 735 730 378 SANYO 586 46 1027 849 609 218 1141 1136 1135 1134 1133 1028 874 860 536 478 187 170 169 168 167 166 152 148 147 146 142 141 140 139 138 137 136 135 134 130 129 128 127 60 59 48 45 SASUK...

Page 14: ...UNI AIR 743 723 VAILLANT 40 VESTEL 976 VIDEOCON 994 186 647 VIVAX 292 VOLTAS 641 409 377 46 5 4 VORTEX 598 WANBAO 1083 319 WEILI 582 WESTINGHOUSE 46 419 WESTPOINT 88 WHIRLPOOL 775 610 596 593 489 271...

Reviews: