Elecom PAR01 Manual Download Page 4

 

 

Tips

 

• Make sure your Original Remote is in Power OFF Status. 
• Make sure your Original Remote set FAN Speed to AUTO and FAN 

SWING to AUTO/ON 

• Press and Hold the Power Key on Original Remote UNTIL AC Master 

indicate Successful or Not. 

• User need at least Learn the OFF (Parameter Value 0), and one 

Temperature Mode (Parameter Value 2 ~ 28) to complete the usage 
model. 

• Keep away from Incandescent Light or Direct Sunlight during 

learning. 

• Make sure IR Transmitter of your Original Remote alight with 

learning diode of AC Master, you may also slight adjust closer or 
further away the distance of two devices. Some of Remotes the 
IR transmitter in hidden behind lens and may not installed center 
of remote. 

• Make sure the power is good on both devices, especially the 

Original remote. Use Fresh Batteries in both devices recommended.

 

 
IR Learning Mapping Table (Parameter Number 25) 
 

Parameter Value 
(Storage Location) 

Thermostat Command & IR Setting 

Storage in Celsius Unit 

Storage  in  Fahrenheit 
Unit 

OFF 

OFF 

ON(Resume) 

ON(Resume) 

17°C COOL 

63°F COOL 

18°C COOL 

64°F COOL 

19°C COOL 

66°F or 67°F COOL 

20°C COOL 

68°F or 69°F COOL 

21°C COOL 

70°F or 71°F COOL 

22°C COOL 

72°F or 73°F COOL 

23°C COOL 

74°F or 75°F COOL 

24°C COOL 

76°F COOL 

10 

25°C COOL 

77°F or 78°F COOL 

11 

26°C COOL 

79°F or 80°F COOL 

12 

27°C COOL 

81°F or 82°F COOL 

13 

28°C COOL 

83°F or 84°F COOL 

14 

29°C COOL 

85°F COOL 

15 

30°C COOL 

86°F COOL 

16 

17°C HEAT 

63°F HEAT 

17 

18°C HEAT 

64°F HEAT 

18 

19°C HEAT 

66°F or 67°F HEAT 

19 

20°C HEAT 

68°F or 69°F HEAT 

20 

21°C HEAT 

70°F or 71°F HEAT 

21 

22°C HEAT 

72°F or 73°F HEAT 

22 

23°C HEAT 

74°F or 75°F HEAT 

23 

24°C HEAT 

76°F HEAT 

24 

25°C HEAT 

77°F or 78°F HEAT 

25 

26°C HEAT 

79°F or 80°F HEAT 

26 

27°C HEAT 

81°F or 82°F HEAT 

27 

28°C HEAT 

83°F or 84°F HEAT 

28 

29°C HEAT 

85°F HEAT 

29 

30°C HEAT 

86°F HEAT 

30 

DRY Mode 

DRY Mode 

Summary of Contents for PAR01

Page 1: ...ivate the device through battery then it can be added into the Z WaveTM network First make sure the primary controller is in the add mode And then power on the device The device will auto start the NW...

Page 2: ...eTM network Get Started Step 1 Apply Power to PAR01 Open the PAR01 Casing InstallCR123 batteries PAR01 will detect the first applied power source to decide what Z Wave device role it will be in after...

Page 3: ...a code that does not support Heat but Original air conditioner supports Heat Function please continue to try next code until the correct one is selected You can record down your Device Code for futur...

Page 4: ...mmended IR Learning Mapping Table Parameter Number 25 Parameter Value Storage Location Thermostat Command IR Setting Storage in Celsius Unit Storage in Fahrenheit Unit 0 OFF OFF 1 ON Resume ON Resume...

Page 5: ...D Display the mapping table with temperatures do not apply due to different type of IR Control Protocol However User may still use OFF ON RESUME DRY AUTO or FAN Key for Learning Because the POWER key...

Page 6: ...the exter nal IR emitter cable to control each air conditioner Control Air Default 0x01 Conditioner 33 0x21 Range 0 to 1 0x00 or 0x01 1 SWING 0 0x00 Swing OFF function 1 0x01 Swing Auto Default Tempe...

Page 7: ...ue is in Hexadecimal Numbering Format if the Gateway only support decimal numbering format please change it to decimal value accordingly Reset to Factory Default Press and Hold PROG button for 3 secon...

Page 8: ...flash the firmware update is succeeded Caution Do not running the OTA when the battery is running low Spec Power by Li 602025 battery Signal Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 00 MHz US...

Page 9: ...AIRWELL 276 670 598 433 432 AKAI 434 ALPIN 718 717 715 714 625 624 AMANA 836 AMCOR 716 668 665 664 663 662 AMERICOOL 430 AMVENT 811 46 APTON 513 839 525 524 523 522 521 520 519 517 516 515 514 508 67...

Page 10: ...345 344 343 33 31 543 357 354 DAITSU 788 DANTEX 841 797 DEER SHUANGLU 592 1047 DELCHI 40 DELONGHI 819 818 787 91 46 503 13 DEMIRDOKUM 42 186 DIAMANT 106 DIMSTAL 545 DOCTOR 846 771 756 722 DONGBAO 652...

Page 11: ...1061 835 830 655 417 1003 999 836 406 256 75 657 535 257 210 209 208 207 198 197 172 156 77 76 23 HAMILTON DIGITAL 186 HAWRIN 894 HERAN 807 40 429 56 421 869 868 867 866 851 850 565 562 550 55 HESSTA...

Page 12: ...2 231 230 229 228 193 70 37 1117 982 981 884 883 882 881 500 355 351 237 186 176 153 93 57 35 340 347 MITSUBISHI HEAVY INDUSTRIES 346 322 319 317 316 278 1095 1084 574 568 356 329 243 36 1174 837 547...

Page 13: ...UI 735 730 378 SANYO 586 46 1027 849 609 218 1141 1136 1135 1134 1133 1028 874 860 536 478 187 170 169 168 167 166 152 148 147 146 142 141 140 139 138 137 136 135 134 130 129 128 127 60 59 48 45 SASUK...

Page 14: ...UNI AIR 743 723 VAILLANT 40 VESTEL 976 VIDEOCON 994 186 647 VIVAX 292 VOLTAS 641 409 377 46 5 4 VORTEX 598 WANBAO 1083 319 WEILI 582 WESTINGHOUSE 46 419 WESTPOINT 88 WHIRLPOOL 775 610 596 593 489 271...