Set Built-
in IR Emitter
Control
( If there have
two or more
Air Condition-
ers with the
same code set
Default: 0xFF
that are used
0 or 255
in the same
32 (0x20) (0x00 or 0xFF)
1
room, user
0(0x00): Disable
can disable
255(0xFF): Enable (Default)
the built-in IR
emitter and
use the exter-
nal IR emitter
cable to
control each
air conditioner
Control Air
Default: 0x01
Conditioner
33 (0x21)
Range 0 to 1 (0x00 or 0x01)
1
“SWING”
0(0x00) : Swing OFF
function
1(0x01) : Swing Auto (Default)
Temperature offset value.
0(0x00)
= 0°C
(Default)
1(0x01)
= 1°C
2(0x02)
= 2°C
Calibrate
3(0x03)
= 3°C
4(0x04)
= 4°C
temperature
37 (0x25)
5(0x05)
= 5°C
reading
255(0xFF) = -1°C
254(0xFE) = -2°C
253(0xFD) = -3°C
252(0xFC) = -4°C
251(0xFB) = -5°C
Temperature offset value.
0(0x00)
= 0°C
(Default)
1(0x01)
= 1°C
2(0x02)
= 2°C