5
WARNING
Consult the manufacturer for information on special installation requirements for
wood, laminate, carpet, vinyl or linoleum flooring.
IMPORTANT
•
Read the instructions carefully before installing the cable system.
•
Remember to measure the resistance four times.
•
Do not install the cable in walls or ceilings.
•
The cable must be embedded in mortar, thinset, concrete or similar material.
•
The minimum installation temperature is 40°F (5°C).
•
The heating cable cannot be cut to length, crossed over itself, or installed too
closely together.
•
It is recommended to use copper wire only.
•
Remember to check that the supply voltage matches the voltage of the cable.
•
Remember to place the labels as written in these instructions.
•
For indoor installation only.
•
Metal structures or materials used for the support of or on which the cable is
installed must be grounded in accordance with
CSA Standard C22.1, Section
10
and the
NEC
.
Please consult the factory for any other questions or advice.