3
1.4 25-year Limited Warranty
For a period of 25 years, to the original owner and/or purchaser, Elec-Trace™
warrants that the heating cable will be free from defects in material, design and
workmanship. The extended warranty is only valid if the warranty certificate has
been properly completed and mailed, and the installation is in accordance with the
installation instructions.
2
Elec-Trace™ Cable System
2.1 Cable Specifications
2.2 Thermostat specifications
Cable construction:
twin conductor
Rated voltage:
120V, 240V
Output:
3W/ft (9.84W/m) ±10%
Heating element size:
40 ft to 800 ft (12.2 to 243.8 m)
Bending radius:
1 in (25.4 mm)
Cable diameter:
1/8 to 1/6 in (3.2 to 4.2 mm)
Conductor insulation:
fluoropolymer (Hytrel®)
Outer insulation:
fluoropolymer or TPE or nylon
Max. ambient temp.:
85°F (30°C)
Min. installation temp.:
40°F (5°C)
Cold lead:
2-wire 16 AWG plus ground braid; 10 ft (3 m) length
Functions:
On/off control, digital display, 7-day programmable
Supply voltage:
120/240 V ±15%, 50/60 Hz
Maximum switching current:
15 amps with GFIC
Temperature control range:
40 to 104°F (5 to 40°C)
Ambient range:
32 to 104°F (0 to 40°C)
Floor temperature sensor:
2-wire, 10-ft lead wire