•   By tamper switch.

 EWF1/EWF1CO comes equipped with a built-in tamper switch intended for 

enclosure supervision: The tamper switch is located on the back of the PCB supervising the 
back side of the enclosure in case the device is illegally detached. 

      Once the enclosure of EWF1/EWF1CO is tampered with, the tamper switch will become trig-

gered. This action will be followed by an alarm, resulting in sending an SMS text message and/
or phone call to the user. The SMS text message contains the violated tamper name. Also, this 
event is added to the Event Log, meanwhile  data messages notifying about triggered tamper 
are delivered to the Monitoring Station and ELDES Cloud Services respectively.

•   Wireless connection loss.

 The wireless connection loss between EWF1/EWF1CO and ELDES 

alarm system leads to alarm. The system identifies this event as a tamper violation and sends 
alarm by SMS text message and phone call to the user (-s) by default. The SMS text message 
contains the wireless device model, wireless ID code and tamper name. The user will also be 
notified by SMS text message as soon as the wireless signal is restored. Also, this event is added 
to the Event Log, meanwhile data messages notifying about wireless connection loss will be 
delivered to the Monitoring Station and ELDES Cloud Services respectively.

The tamper will not operate if the wireless zone (-s) is disabled.

6.  TEMPERATURE SENSOR

The device comes equipped with a built-in temperature sensor allowing to monitor the temperature 
of the area surrounding EWF1/EWF1CO device. When using the with EPIR3 alarm system, you may 
set the MIN and MAX temperature thresholds ranging from +5°C to +45°C resulting in SMS text mes-
sage delivery to the listed user phone number once exceeded. The accuracy of temperature measure-
ment is +/-1°C. Also, this event is added to the Event Log, meanwhile data messages notifying about 
exceeded temperature threshold are delivered to the Monitoring Station and ELDES Cloud Services 
respectively.

Summary of Contents for EWF1

Page 1: ...WIRELESS SMOKE DETECTOR WIRELESS SMOKE CO DETECTOR COMPLIES WITH EN 14 604 2005 USER GUIDE V2 0 EWF1 EWF1CO EN FR ES PT ...

Page 2: ...EWF1 EWF1CO va alerter le système Eldes de cet événement EWF1 es un detector de humo inalámbrico EWF1CO es un detector de monóx ido de carbono CO inalámbrico combinado con el detector de humo En caso de que se produzca la detección del aumento de humo o monóxido de carbo no EWF1 EWF1CO indicará la alarma y notificará al sistema ELDES sobre el evento EWF1 é um detector fotoelétrico de fumaça sem fi...

Page 3: ......

Page 4: ...4 EWF1 EWF1CO EN FR ES PT ...

Page 5: ...0 9m 2 95 ft 0 9m 2 95 ft MIN 5 C 41 F MAX 45 C 113 F MIN 5 C 41 F MAX 45 C 113 F MIN 5 C 41 F MAX 45 C 113 F ...

Page 6: ...2 1 2 1 1 2 1 ...

Page 7: ...1 EWF1CO EN FR ES PT 1 2 3 MIN 1 2 TEST ELDES Configuration Tool WAIT FOR 3 MIN ATTENDRE 3 МИН ESPERE POR 3 MIN AGUARDE 3 MIN PRESS FOR 2 SEC PRESSER PENDANT 2 SEC PRESIONE DURANTE 2 SEG PRESSIONE POR 2 SEG ...

Page 8: ...ocations Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized detector with unwanted alarm control for this areas In areas with high humidity like bathrooms or areas near dishwashers or washing machines Install at least 3m 9 84ft away from these areas Near air returns or heating and cooling supply vents Install at least 1m 3 28f...

Page 9: ...Headache increased heart rate dizziness and nausea within 20 min death in less than 2 hours ppm Parts Per Million is used to describe concentrations of contaminants in air In the event of ALARM caused by a critical CO concentration level keep calm and carry out the following actions in the priority order Open all windows and doors to increase the rate of ventilation Turn off the appliances and sto...

Page 10: ...n displayed by EKB2 LCD keypad only for ESIM364 and a warning delivery to the listed user by SMS text message This level causes no zone alarm when reached as well as it results in zone restore event in case the CO concentration of 300ppm or more crit ical level 4 has been reached and decreased to 30 49ppm afterwards Also data messages notifying about CO critical level 1 and gas fault detection are...

Page 11: ...en pressed Also data messages notifying about CO critical level 4 and gas fault detection are delivered to ELDES Cloud Services and added to both Event Log and Fault Log respectively CO unit fault when CO sensor s 7 year lifetime period has ended or in case of any technical issue that has occurred Indicated by a fault indication displayed by EKB2 LCD keypad only for ESIM364 and notification delive...

Page 12: ...When testing EWF1 EWF1CO using ELDES Configuration Tool software the detector will provide short beeps The CO self test on EWF1CO will be carried out by pushing the TEST WEEKLY button at carbon monoxide concentration below 30ppm The button release will be followed by a built in siren sound after a 10 second period Successful test 5 beeps each lasting for 100 ms Failed test 1 beep lasting for 1 sec...

Page 13: ...devices EWF1 EWF1CO device that detected smoke will auto reset when the smoke clears while the rest of EWF1 EWF1CO devices will continue to sound in accordance with the set time period by default 30 seconds that can be managed by ELDES Configuration Tool software Interconnection will commence when CO critical level 4 has been reached see 2 2 CO Alarm Restore and Fault Indications 4 3 BATTERY REPLA...

Page 14: ...using EVE CR9V P or Energizer LA522 battery 4 4 RESTORING THE DEFAULT PARAMETERS 1 Remove the battery from EWF1 EWF1CO 2 Press and hold the RESET button 3 Insert the battery back to EWF1 EWF1CO 4 Hold the RESET button until you hear a short beep 5 Release the RESET button 5 EWF1 EWF1CO ZONE AND TAMPER Upon successful device pairing process the system adds wireless zone s as follows EWF1 1 Fire typ...

Page 15: ... text message and phone call to the user s by default The SMS text message contains the wireless device model wireless ID code and tamper name The user will also be notified by SMS text message as soon as the wireless signal is restored Also this event is added to the Event Log meanwhile data messages notifying about wireless connection loss will be delivered to the Monitoring Station and ELDES Cl...

Page 16: ...clears EWF1 is a wireless photoelectric based smoke detector designed to detect smouldering fire before bursting into flame while EWF1CO is a wireless electrochemical based carbon monoxide CO detec tor combined with photoelectric based smoke detector designed to detect smouldering fire When the concentration of smoke CO exceeds a given threshold the system will cause alarm resulting in built in si...

Page 17: ...ange 0 400 ppm Alarm sound level 85dB at 3m 85dB at 9 84ft EWF1 lifetime 10 years EWF1CO lifetime 7 years Range of operating temperatures 5 45 C 41 113 F Humidity 0 90 RH 0 40 C 0 90 RH 32 104 F non condensing Dimensions 110mm 4 33in Ø The specified operation time applies in case of no alarms and when having the device tested once a week The operation time might vary in different conditions Techni...

Page 18: ......

Page 19: ...Made in the European Union www eldes lt ...

Reviews: