11
EWF1-EWF1CO
EN
by EKB2 LCD keypad (only for ESIM364) and a warning delivered to the listed user by SMS text
message. This level causes no zone alarm when reached. Also, data messages notifying about
CO critical level 3 and gas fault detection are delivered to ELDES Cloud Services and added to
both Event Log and Fault Log respectively.
• CO critical level 4
– when CO concentration of 300ppm and more is reached. This level will
cause an alarm when reached resulting in the unit emitting a 2-second beep every 5 seconds
and LED indicator flash. Meanwhile the system will notify the listed user by SMS text message
and the monitoring station as well as all wired and wireless sirens will emit a pulsating sound
based on the Fire-type zone operational description and activate the interconnection feature (by
default - enabled; see
4.2. Interconnection
). All wired and wireless sirens can be silenced by
disarming the system. However, EWF1CO built-in siren will remain active until the TEST WEEK-
LY button has been pressed. Also, data messages notifying about CO critical level 4 and gas fault
detection are delivered to ELDES Cloud Services and added to both Event Log and Fault Log
respectively.
• CO unit fault
– when CO sensor’s 7-year lifetime period has ended or in case of any technical
issue that has occurred. Indicated by a fault indication displayed by EKB2 LCD keypad (only for
ESIM364) and notification delivery to the listed user via SMS text message and the monitoring
station. Please contact your local suppli er for repair service.
2.3 CLEANING AND PRECAUTIONS DURING USE
Clean the detector at least once a month to remove dust, dirt, or debris. Using the soft brush or
wand attachment of a vacuum cleaner, vacuum all sides and cover of the detector. Be sure all the
vents are free of debris. If necessary, use a damp cloth to clean the detector cover.
Some household substances can affect the sensitivity of the detectors in a short or long term. Avoid
the use of model paint, model glue or nail polish remover close to the detector. Do not use aerosol
sprays, household cleaners, polishes or perfumes close to the device.
Do not attempt to remove the cover to clean inside the detector. This will void your warranty.