3. CONFIGURING AND PAIRING WITH THE SYSTEM
ELDES
Configuration Tool
For more details on how to configure and pair the device with the system,
please refer to ELDES Configuration Tool software’s HELP section or to
ELDES alarm system’s installation/user manual.
If you are unable to pair the wireless device, please restore the
parameters of the wireless device to default and try again (see
4.4 RESTORING THE DEFAULT PARAMETERS
for more details).
4. MAINTENANCE
4.1 TESTING THE UNIT
• The TEST WEEKLY button verifies if EWF1/EWF1CO is operational. Firmly push the TEST
WEEKLY button and the detector will sound a loud beep. The alarm will stop sounding after
releasing the TEST WEEKLY button. When testing EWF1/EWF1CO using ELDES Configuration
Tool software, the detector will provide short beeps.
• The CO self-test on EWF1CO will be carried out by pushing the TEST WEEKLY button at carbon
monoxide concentration below 30ppm. The button release will be followed by a built-in siren
sound after a 10-second period:
• Successful test - 5 beeps each lasting for 100 ms.
• Failed test - 1 beep lasting for 1 sec. Please contact your local suppli er for repair service.
• Stand at arm’s length from the detector when testing.
• Test the detectors weekly and upon returning from vacation or when no one has been in the
household for several days.
• Test each detector to be sure it is installed correctly and operating properly.
• DO NOT use an open flame to test this detector. You may ignite and damage the detector or your home.
• If the detector does not sound, please check the battery and signal level using ELDES Configu-
ration Tool software.