22
EN
ET083 2G/3G COMMUNICATOR V1.0
•
Contact ID –
Ademco Contact ID data format.
•
Scancom
*** - Data format complying with Scancom/BSIA Fast Format protocol requirements.
8. On eT083: Open
Events Log
section to monitor the activity.
9. On eT083****: If required, the Account number set on the alarm panel can be overridden under
System
→
Security Panel Settings
section. For
more details, please refer
9. MONITORING STATION PHONE NUMBER AND ACCOUNT REPLACEMENT
.
*
Necessary only when using RING/TIP interface communication wiring method.
**
Necessary only when using Keybus interface communication wiring method. When using RING/TIP interface communicates wiring meth-
od, it might be useful to replace the monitoring station phone number retrieved from the alarm panel.
***
Supported only when using RING/TIP interface communication wiring method.
**** Useful only when using RING/TIP interface communication wiring method.
For more details on the parameters located under
Voice Calls Settings
section, please refer to
ELDES Configuration Tool
software’s HeLP
file.
7.2.2. SMS Method
Based on the communication wiring method that is being used, using this method the communicator:
•
RING/TIP interface
– Retrieves Ademco Contact ID data from the alarm panel, converts it into user-understandable text and delivers to up
to 5 listed users by SMS text message. Before proceeding with any further configuration, please complete the steps provided in
6.1. RING/TIP
Interface
.
•
Keybus or Serial interface
– Retrieves serial data from the alarm panel, converts it into Ademco Contact ID data followed by conversion into
user-understandable text and delivery to up to 5 listed users by SMS text message. Before proceeding with any further configuration, please
complete the steps provided in
6.2. Keybus and Serial Interfaces
.
To set the communicator to transmit data using this communication method, please proceed as follows:
1. On alarm panel*: enable Ademco Contact ID mode.
2. On alarm panel*: Set random Account number.
3. On alarm panel*: Set random monitoring station phone number; single digit is sufficient.
4. On eT083: Connect the device to the computer via USB cable and run
ELDES Configuration Tool
software.
5. On eT083: Open
System
→
Settings
section and proceed as follows:
a. enable
Advanced Mode
.
b. Set SMS as Primary connection. In addition,
Backup 1
and
Backup 2
connections can be set under this section.
6. On eT083: Open
Messaging Settings
section and proceed as follows:
a. Set up to 5 user phone numbers that will be permitted to receive the data converted into user-understandable text by SMS text message. The
supported phone number formats are the following:
• International (with plus)
– The phone numbers must be entered starting with plus and an international country code in the following
format: +[international code][area code][local number], example for
UK: +44170911XXXX1
.
• International (with 00)
– The phone numbers must be entered starting with 00 and an international country code in the following for-
mat: 00[international code][area code][local number], example for
UK: 0044170911XXXX1
.
• Local
– The phone numbers must be entered starting with an area code in the following format: [area code][local number], example for
UK: 0170911XXXX1
.
b. Manage SMS text message content reflecting the Ademco Contact ID data message structure.
c. Based on the alarm panel’s documentation, ensure that all CID event codes supported by the alarm panel are added under the Messaging
Settings section, otherwise the communicator will be unable to deliver a certain event.
7. On eT083: Open
Events Log
section to monitor the activity.
* Necessary only when using RING/TIP interface communication wiring method.
For more details on the parameters located under
Messaging Settings
section, please refer to
ELDES Configuration Tool
software’s HeLP file.
7.2.3. IP Method
Based on the communication wiring method that is being used, using this method the communicator:
•
RING/TIP interface
– Retrieves Ademco Contact ID data from the alarm panel, converts it into eGR100, Kronos or SIA IP protocol and transmits
to the monitoring station via 2G/3G network or ethernet connection using eLAN3-ALARM device. Before proceeding with any further configu-
ration, please complete the steps provided in
6.1. RING/TIP Interface
.
•
Keybus or Serial interface
– Retrieves serial data from the alarm panel, converts it into Ademco Contact ID
followed by data conversion to
eGR100, Kronos or SIA IP protocol and transmission to the monitoring station via 2G/3G network or ethernet connection using eLAN3-ALARM
device. Before proceeding with any further configuration, please complete the steps provided in
6.2. Keybus and Serial Interfaces
.
To set the communicator to transmit data using this communication method, please proceed as follows:
1. On alarm panel*: enable Ademco Contact ID mode.