ET083 2G/3G COMMUNICATOR V1.0
7.1. Basic Mode
The communication method of Basic mode is selected by jumper position on the SeT/MODe pins on board. Basic mode features the following
communication methods:
•
Voice Calls
•
SMS
•
Voice Calls + SMS
•
IP
Basic mode is supported only when eT083 is linked up with the alarm panel via RING/TIP interface.
The jumper position on SeT/MODe pins becomes ineffective as soon as Advanced mode is enabled.
7.1.1. Voice Calls Method
Using this method the communicator retrieves Ademco Contact ID or 4+2 data from the alarm panel and transmits it to the monitoring station
via 2G/3G audio direct channel without influencing the data itself. Before proceeding with any further configuration, please complete the steps
provided in
6.1. RING/TIP Interface
.
To set the communicator to transmit data using this communication method, please proceed as follows:
1. On alarm panel: enable Ademco Contact ID or Ademco 4+2 mode.
2. On alarm panel: Set valid Account number.
3. On alarm panel: Set the monitoring station phone number (-s) in one of the following formats:
• International (with 00)
– The phone numbers must be entered starting with 00 and an international country code in the following format:
00[international code][area code][local number], example for
UK: 0044170911XXXX1.
• Local
– The phone numbers must be entered starting with an area code in the following format: [area code][local number], example for
UK:
0170911XXXX1.
4. On eT083: ensure that NO jumpers are set on SeT/MODe pins on board.
18
SET
MODE
5. If required to override the Account number set on the alarm panel, please use Voice Calls communication method provided by Advanced mode
(see
7.2.1. Voice Calls Method
). In addition, please refer to
10. MONITORING STATION PHONE NUMBER AND ACCOUNT REPLACEMENT
.
In the event of failure using this communication method, please refer to
8. 2G/3G MODEM SETTINGS
or use Voice Calls communi-
cation method provided by Advanced mode (see
7.2.1. Voice Calls Method
).
7.1.2. SMS Method
Using this method the communicator retrieves Ademco Contact ID data from the alarm panel, converts it into user-understandable text and delivers
to up to 5 listed users by SMS text message. Before proceeding with any further configuration, please complete the steps provided in
6.1. RING/
TIP Interface
.
To set the communicator to transmit data using this communication method, please proceed as follows:
1. On alarm panel: enable Ademco Contact ID mode.
2. On alarm panel: Set random Account number.
3. On alarm panel: Set random monitoring station phone number; single digit is sufficient.
4. On eT083: Set a jumper on
MODE
pins on board.