Safety instructions
Please read and follow these safety guidelines and assembly instructions in order to maintain safety of operators and people around:
• GSM control system ESIM120 (further referenced as the system or device) contains an integrated radio transceiver operating in
GSM 850/900/1800/1900 MHz bands.
DO NOT use the system where it can interfere with other devices and cause any potential danger.
• DO NOT mount the system next to medical equipment or devices, if they require so.
• DO NOT use the system in hazardous environment.
• DO NOT expose the system to high humidity, chemical environment or mechanical impacts.
• DO NOT attempt to personally repair the system.
• System label is on the bottom side of the device.
System ESIM120 is a device mounted in limited access areas. Any system repairs must be done only by qualified, safety aware
personnel.
Mains power must be disconnected before any installation or tuning work starts. The system installation or maintenance
must not be done during stormy conditions.
The system must be powered by main 10-24V 50Hz ~200mA AC or 10-24V
200mA DC power supply which must be
approved by LST EN 60950-1 standard and be easily accessible nearby the device. When connecting the power supply to the
system, switching the terminals places does not have any affect.
Any additional devices linked to the system ESIM120 (computer, sensors, relays etc.) must be approved by LST EN 60950-1
standard.
External power supply can be connected to AC mains only inside
installation room with automatic 2-pole circuit breaker capable of
disconnecting circuit in the event of short circuit or over-current
condition. Open circuit breaker must have a gap between con-
nections of more than 3mm and the disconnection current 5A.
Fuse F1 model MINISMDC050F 0.5A. Blown fuse cannot be replaced by the user and the replacement fuses have to be exactly the
same as indicated by the manufacturer.
The device is fully turned off by disconnecting 2-pole switch off device of the external power supply or any other linked
device that the system ESIM120 is powered from.
The WEEE (Waste Electrical and Electronic Equipment) marking on this product or its documentation indicates that in the EU the
product must not be disposed of together with household waste.
Phase
AC 230V
50 Hz/DC 24V
USB cable
Null
ESIM120
PE
AC/DC
If you use I security class computer for setting the parameters it must be connected to earth.