16
Manufacturer default C1 and C2 output names: C1 –
Controller1
, C2 –
Controller2
. The
length of each output name can be up to 10 characters including space symbol. Send the
following SMS message in order to set a new output name.
This feature turns off the output and changes the output startup state to normally closed (NC)
at the same time. It is possible to turn off the output by output number or by output name.
This feature turns on the output and changes the output startup state to normally closed (NC)
at the same time. It is possible to turn on the output by output number or by output name.
Output Name
Turn OFF Output
/ Output Startup
State - NO
Turn ON Output
/ Output Startup
State - NC
SMS text:
XXXX_Cx:NewOutpuName
Value:
x – output number; range – [1.. 2]
Example:
1111_C2:GATES02
SMS text:
XXXX_Cx:OFF
or
XXXX_OutputName:OFF
Value:
x – output number; range – [1.. 2]
Example:
XXXX_Gates2:OFF
SMS text:
XXXX_Cx:ON
or
XXXX_OutputName:ON
Value:
x – output number; range – [1.. 2]
Example:
XXXX_C2:ON
2.7 Output Configuration
NOTE:
Semi-colon characters, parameter names and/or values are not allowed in controller names, eg. PSW, STATUS, ON,
OFF etc.