Page 1: ...ordered separately RCR02E5002A01 2TE Technical Data Frequency 868 30 MHz Modulation FSK Coding Easywave Power supply 230 V AC 50 Hz Output 2 potential free relay contacts 16 A normally open Power consumption 0 6 W standby Connected load see Load Table Operating temperature 20 C to 60 C Dimensions W L H 34 5 89 6 62 8 mm Weight 108 g Load Table Load type max load Ohmic load Incandescent lamps 230 V...

Page 2: ...elect operation Mode button Select operating mode Channel 1 button Manually switch output ON OFF Select output 1 Channel 2 button Manually switch output ON OFF Select output 2 Channel 3 button Manually switch output ON OFF Select output 3 Channel 4 button Manually switch output ON OFF Select output 4 2 A Installing the Receiver A2 Electrical Connection Connection Diagram RCR02 4TE Cable cross sect...

Page 3: ...e min 100 s max 1 66 h Shutdown warning 30 seconds before the time expires ON retrig OFF ON retrig OFF ON retrig ON retrig ON retrig ON retrig s x 1 Multiplier 1 Switching time min 1 s max 60 s No shutdown warning ON retrig OFF ON retrig OFF ON retrig ON retrig ON retrig ON retrig s x 10 Multiplier 10 Switching time min 10 s max 10 min No shutdown warning ON retrig OFF ON retrig OFF ON retrig ON r...

Page 4: ...0 0 0 00 30 0 05 00 0 50 00 8 20 00 Conversion seconds with multiplier in time Hr min sec B3 Conversion table of TIMER II Multiplier Seconds Counter 1 10 100 1000 31 1 0 00 31 0 05 10 0 51 40 8 36 40 32 2 0 00 32 0 05 20 0 53 20 8 53 20 33 3 0 00 33 0 05 30 0 55 00 9 10 00 34 4 0 00 34 0 05 40 0 56 40 9 26 40 35 5 0 00 35 0 05 50 0 58 20 9 43 20 36 6 0 00 36 0 06 00 1 00 00 10 00 00 37 7 0 00 37 0...

Page 5: ...ng mode The maximum base time is 60 seconds after this time the measurement stops automatically The set switching time applies to all of the pro grammed transmission codes in this operating mode for the corresponding output The switching times can be configured individu ally for each output and each TIMER II operating mode If the switching time for an operating mode is changed it is also applied t...

Page 6: ... respective output are re set Operation 1 Press button Display Note P P 1x briefly or 2x briefly LED 2TB flashes LED 1TB flashes Programming mode started M repeatedly Select delete function L 1 2 3 4 LED 1 2 3 4 and LED xTB flash Select output Only one output can be selected Output can be changed as often as required P until LED output and 2TB and 1TB flash quickly Delete mode started Cancel 1x P ...

Page 7: ...ent any product defects arising from production or mate rial faults Any unauthorised tampering with or modifica tions to the product shall render this warranty null and void Conformity ELDAT GmbH hereby declares that the radio equipment type RCR02 is in compliance with the Directive 2014 53 EU The full text of the EU declaration of conformity can be obtained at the following internet address www e...