B
Operation
B1
Operating and Display Elements
DISPLAY
Operating Status
Programming Mode
LED
GREEN
PWR
Power
Supply voltage is on, LED
is lit.
LED
RED
2TB
1TB
2-button operation
1-button operation
LED 2TB flashes when a
wireless signal is detected.
Displays the selected
operation.
Signals the programming or
delete mode.
1
LED output 1 flashes
Relay 1 switched
Displays the output selected
for programming.
2
LED output 2 flashes
Relay 2 switched
3
LED output 3 flashes
Relay 3 switched
4
LED output 4 flashes
Relay 4 switched
Digital Display
....
Upon receiving a program
-
med transmission code, the
corresponding operating mode
is displayed for 2 s.
Displays the selected opera-
ting mode.
Displays the seconds during
Timer II programming.
OPERATING
Operating Status
Programming Mode
Programming button
Start programming mode,
select operation
Mode button
Select operating mode
Channel 1 button
Manually switch output
ON/OFF
Select output 1
Channel 2 button
Manually switch output
ON/OFF
Select output 2
Channel 3 button
Manually switch output
ON/OFF
Select output 3
Channel 4 button
Manually switch output
ON/OFF
Select output 4
2
A
Installing the Receiver
A2
Electrical Connection
Connection Diagram RCR02 4TE
Cable cross-sections
rigid cables:
0.5 – 2.5 mm²
flexible cables with wire
end ferrules:
0.5 – 1.5 mm²
Connection external antenna
ACC-ANT50-03-21P
Connection external antenna
ACC-ANT50-03-21P
When changing the programming mode, all outputs are switched off and no switching operations
are possible.
When returned to operating mode, the outputs remain switched off.
230 V AC
50 Hz
N
L
230 V AC
50 Hz
N
L
RCR02 2TE
RCR02 4TE
Connection external
antenna:
Connect the black anten-
na cable to the antenna
terminal
and the white cable to
the functional earth termi-
nal on.
Note:
Mount the an-
tenna away from metal
housing.
Connection Diagram RCR02 2TE