C1 Programming the Transmitter
If a previously programmed transmitter is pro-
grammed again in the same output, the previous
operating mode is
overwritten with the new operating mode.
32 transmission codes can be programmed per
output.
.
Operation
[Press the button]
Display
Note
Programming 2TB
P
1x briefly
LED 2TB flashes
Programming mode 2-button operation
started.
M
repeatedly OM number in
digital display
Select the operating mode (OM).
1/2/3/4
LED 1/2/3/4 and
LED 2TB flashes
Select switching output.
Only one output can be active at any time,
change as often as required.
Transmitter
button
Tx
1x briefly
LED 2TB and LED
of the selected output
light up
Transmission code is programmed.
When all the LEDS go out, the receiver
is ready for operation.
Programming 1TB
P
2x briefly
LED 1TB flashes
Programming mode 1-button operation
started.
M
repeatedly
OM number in
digital display
Select the operating mode (OM).
1/2/3/4
LED 1/2/3/4 and
LED 1TB flash
Select switching output.
Only one output can be active at any time,
change as often as required.
Transmitter
button
Tx
1x briefly
LED 1TB and LED
of the selected output
flash
Transmitter is programmed.
When all the LEDS go out, the receiver is
ready for operation.
C Programming
C2
Setting TIMER II
The switching times for operating modes 7, 8, 9,
A and C can be set individually for each output.
These switching times apply to every transmissi-
on code programmed with this operating mode in
the output.
The switching time is calculated using the base
time measured during programming and the mul-
tiplier for the selected operating mode.
The maximum base time is 60 seconds, after this
time the measurement stops automatically.
The set switching time applies to all of the pro-
grammed transmission codes in this operating
mode for the corresponding output.
The switching times can be configured individu
-
ally for each output and each TIMER II operating
mode.
If the switching time for an operating mode is
changed, it is also applied to the programmed
transmitter in this operating mode for the same
output!
Operation
[Press the button]
Display
Note
1.
P
1x briefly
LED 2TB flashes
Programming mode started.
2.
M
repeatedly
OM number in
digital display
Select TIMER operating mode to be set.
(7, 8, 9, A or C)
3.
1/2/3/4
LED 1/2/3/4 and
LED 2TB flashes
Select output.
Only one output can be selected.
4.
P
> 1,6 s
LED 2TB + 1TB flash
alternately
LED 1/2/3/4 light up
Display counts up the
seconds
The base time measurement for the timer
has started. In the display the seconds count
upwards from 1-10(0) a maximum of 6 times.
After a maximum of 60 s, the measurement
automatically stops.
5.
P
1x briefly
LED output and 2TB
and 1TB light up
The base time measurement has stopped.
The measured time is multiplied by the multi-
plier of the chosen OM and the new switching
time is saved. When all the red LEDS go out,
the receiver is ready for operation.
If no buttons are pressed within 30 seconds (not during the time measurement), the RCR02
automatically switches to operating mode. The settings are not saved.
Programming can be cancelled by pressing the P button several times. The order is:
2TB --> 1TB --> Operating mode. In operating mode, all red LEDS and the display are off,
as long as no output is activated..
Tx
P
M
1/2/3/4
5
Select the
operating
mode
Start program-
ming mode and
select operation
Select
output
Send transmission code