Intended Use

The device is intended for mounting on a DIN rail 

in a distribution box or a control cabinet in dry 

rooms. The unit may only be used as a wireless 

receiver for activating electrical devices in accord-

ance with the load table. To be operated with Ea-

sywave wireless transmitters.
The manufacturer shall not be liable for any dam-

age caused by improper or non-intended use.

Safety Advice

 Before installing the device, carefully 

read through this operating manual! 

 

Caution! Electrical installation must only be 

carried out by a qualified electrician, failure 

to do so may result in fire or electric shock.

Observe the applicable laws, standards and re-

gulations as well as the operating instructions of 

the appliances to be switched!
This device is only intended for indoor use in 

dry and dust-free rooms.
Have faulty devices checked by the manufac-

turer!

Do not make any modifications to the device!

Setting up the Receiver

A  Installing the Receiver ..............................

1

 

A1  Mounting the Receiver ....................... 1

 

A2  Electrical Connection ......................... 2

B Operation

 ...................................................

2

 

B1  Operating and Display Elements ....... 2

 

B2  Operating Modes ............................... 3

 

B3  Conversion table for TIMER .............. 4

C Programming

 ............................................

5

 

 

C1  Programming the Transmitter ............ 5

 

C2  Setting the TIMER...............................5

   C3  Deleting the Transmitter .....................  6

  C4 Reset ................................................. 6

D  General Information

 ..................................

8

 A  

Installing the Receiver

A1 

Mounting the Receiver

The device is intended for installation on a stand-

ard DIN rail (35 x 7.5 mm). Pull out the slide to 

allow fixing through mounting points. 
Only a qualified electrician may install, connect 

in accordance with the connection diagram and 

set up the receiver.

Please note the „5 safety rules“ for electri

-

cians!

1.  Switch  off  the  power  supply.  Follow  the  „5 

safety rules“!

2.   Mount the RCR02 onto the rail.
3.  Connect the cables for the power supply and 

for the devices in accordance with the con-

nection diagram (see page 2).

4.  Switch  on  the  supply  voltage.  Follow  the  „5 

safety rules“!

5.  Programme the receiver according to the op-

erating manual (see pages 4-5).

In unfavourable environmental conditions, the ex-

ternal antenna ACC-ANT50-03-21P can be used 

to improve wireless reception. This is not included 

in the delivery and can be ordered separately.

RCR02E5002A01   

2TE

Technical Data

Frequency: 

868.30 MHz

Modulation:  

FSK

Coding:  

Easywave

Power supply: 

230 V AC 50 Hz

Output: 

2 potential-free relay  

 

contacts 16 A  

 

(normally open) 

Power consumption: 

0.6 W standby

Connected load: 

see Load Table

Operating temperature:  -20 °C to +60 °C

Dimensions (W/L/H):   34.5 /89.6/62.8 mm

Weight: 

108 g

Load Table

Load type

max. load

Ohmic load: 

 

Incandescent lamps, 230 V 

halogen lamps etc.

16 A / 3,680 VA

IInductive load: 

 

Halogen lamps with wound 

transformers (transformer at 

least 85% loaded)

  3 A / 690 VA

Non- or serial-compensated 

fluorescent lamps with ferro

-

magnetic ballasts

  3 A / 690 VA

Parallel-compensated fluores

-

cent lamps with ferromagnetic 

ballasts

  3 A / 720 VA

Electronic ballast capacity: 

electronic ballasts, electronic 

transformers, etc.

  4 A / 920 VA

Function

The RCR02E 2TE DIN rail receiver is used for the 

potential-free activation of two mains-powered 

devices.

The receiver can be operated in ON/OFF, PULSE 

and DEAD MAN‘S SWITCH modes. The ON/OFF 

mode can also be used with two TIMER functions 

and a LOGIC function.

Scope of Delivery

DIN Rail receiver RCR02 2TE,  

operating manual

DIN Rail receiver   RCR02

EN

RCR02E5004A01   

4TE

Technical Data

Frequency: 

868.30 MHz

Modulation:  

FSK

Coding:  

Easywave

Power supply: 

230 V AC 50 Hz

Output: 

2 potential-free relay  

 

contacts 16 A  

 

(normally open)

 

2 potential-free relay  

 

contacts 16 A  

 (change-over)

Power consumption:  0.6 W standby

Connected load: 

see Load Table

Operating temperature: -20 °C to +60 °C

Dimensions (W/L/H):  70.5 /89.6/62.8 mm

Weight: 

186 g

Load Table

Load type

max. load

Ohmic load: 

 

Incandescent lamps, 230 V 

halogen lamps etc.

16 A / 3,680 VA

IInductive load: 

 

Halogen lamps with wound 

transformers (transformer at 

least 85% loaded)

  3 A / 690 VA

Non- or serial-compensated 

fluorescent lamps with ferro

-

magnetic ballasts

  3 A / 690 VA

Parallel-compensated fluores

-

cent lamps with ferromagnetic 

ballasts

NO 

  3 A / 720 VA

NC

 1.5 A / 345 VA

Electronic ballast capacity: 

electronic ballasts, electronic 

transformers, etc.

   4 A / 920 VA

Function

The RCR02E 4TE DIN rail receiver is used for the 

potential-free activation of four mains-powered 

devices.

The receiver can be operated in ON/OFF, PULSE 

and DEAD MAN‘S SWITCH modes. The ON/OFF 

mode can also be used with two TIMER functions 

and a LOGIC function.

Scope of Delivery

DIN Rail receiver RCR02 4TE, 

operating manual

Models

1

Summary of Contents for Easywave RCR02E5002A01

Page 1: ...ordered separately RCR02E5002A01 2TE Technical Data Frequency 868 30 MHz Modulation FSK Coding Easywave Power supply 230 V AC 50 Hz Output 2 potential free relay contacts 16 A normally open Power consumption 0 6 W standby Connected load see Load Table Operating temperature 20 C to 60 C Dimensions W L H 34 5 89 6 62 8 mm Weight 108 g Load Table Load type max load Ohmic load Incandescent lamps 230 V...

Page 2: ...elect operation Mode button Select operating mode Channel 1 button Manually switch output ON OFF Select output 1 Channel 2 button Manually switch output ON OFF Select output 2 Channel 3 button Manually switch output ON OFF Select output 3 Channel 4 button Manually switch output ON OFF Select output 4 2 A Installing the Receiver A2 Electrical Connection Connection Diagram RCR02 4TE Cable cross sect...

Page 3: ...e min 100 s max 1 66 h Shutdown warning 30 seconds before the time expires ON retrig OFF ON retrig OFF ON retrig ON retrig ON retrig ON retrig s x 1 Multiplier 1 Switching time min 1 s max 60 s No shutdown warning ON retrig OFF ON retrig OFF ON retrig ON retrig ON retrig ON retrig s x 10 Multiplier 10 Switching time min 10 s max 10 min No shutdown warning ON retrig OFF ON retrig OFF ON retrig ON r...

Page 4: ...0 0 0 00 30 0 05 00 0 50 00 8 20 00 Conversion seconds with multiplier in time Hr min sec B3 Conversion table of TIMER II Multiplier Seconds Counter 1 10 100 1000 31 1 0 00 31 0 05 10 0 51 40 8 36 40 32 2 0 00 32 0 05 20 0 53 20 8 53 20 33 3 0 00 33 0 05 30 0 55 00 9 10 00 34 4 0 00 34 0 05 40 0 56 40 9 26 40 35 5 0 00 35 0 05 50 0 58 20 9 43 20 36 6 0 00 36 0 06 00 1 00 00 10 00 00 37 7 0 00 37 0...

Page 5: ...ng mode The maximum base time is 60 seconds after this time the measurement stops automatically The set switching time applies to all of the pro grammed transmission codes in this operating mode for the corresponding output The switching times can be configured individu ally for each output and each TIMER II operating mode If the switching time for an operating mode is changed it is also applied t...

Page 6: ... respective output are re set Operation 1 Press button Display Note P P 1x briefly or 2x briefly LED 2TB flashes LED 1TB flashes Programming mode started M repeatedly Select delete function L 1 2 3 4 LED 1 2 3 4 and LED xTB flash Select output Only one output can be selected Output can be changed as often as required P until LED output and 2TB and 1TB flash quickly Delete mode started Cancel 1x P ...

Page 7: ...ent any product defects arising from production or mate rial faults Any unauthorised tampering with or modifica tions to the product shall render this warranty null and void Conformity ELDAT GmbH hereby declares that the radio equipment type RCR02 is in compliance with the Directive 2014 53 EU The full text of the EU declaration of conformity can be obtained at the following internet address www e...

Page 8: ...UM177683 0519 EN ELDAT GmbH Im Gewerbepark 14 15711 Königs Wusterhausen Germany Phone 49 0 33 75 90 37 310 Fax 49 0 33 75 90 37 90 Internet www eldat de E Mail info eldat de ...