background image

GB DIP-804/00 /2

9

- The belt breakage

indicator lights up after
the PROTECTIONS

ACTIVE

indicator

lights up

- The low oil pressure

indicator lights up after
the PROTECTIONS

ACTIVE

indicator

lights up

- The overheating

indicator lights up

- Defective device

TYPE OF PROBLEM

PROBABLE CAUSES

REMEDIAL INTERVENTIONS

ENGINE STOPS FOR
ANOMALLY THOUGH
ALL APPEARS TO BE
REGULAR

- Check the function of the charge alternator

- Test and, if necessary, replace the oil

pressure switch

- Test and, if necessary, replace the

thermostat

- Simulate the functioning of the device (see

DEVICE TEST on page 5) and if necessary
replace it (*)

Turn the key to zero to reset the functioning

Before replacing the device, we suggest that you telephone one of our technicians for advice.
When your technician-electrician phones he must have the scheme on page 5 available together with the
following information:

- Type of equipment installed
- Problem encountered
- Condition of the indicators on the dashboard when the problem occurred
- Any remedial interventions performed

[*] DEVICE REPLACEMENT

TROUBLE SHOOTING

Summary of Contents for DIP-804/00

Page 1: ...CIENT BATTERY CHARGE ALTERNATOR BELT BREAKAGE LOW OIL PRESSURE OVERHEATING FUEL RESERVE without stopping engine OIL AND BATTERY INDICATORS INTEGRATED INTO THE DEVICE GB DIP 804 00 2 1 DIP 804 00 INSTR...

Page 2: ...N THE FOLLOWING CONDITIONS Where the environmental temperature is outside the limits indicated in the enclosed technical sheet Where there are high levels or heat from radiation caused by the sun oven...

Page 3: ...the relevant anomaly is detected OIL AND BATTERY INDICATORS ANOMALY INDICATORS After a 3 second delay for Immediately for OIL PRESSURE SWITCH OVERHEATING THERMOSTAT BATTERY CHARGE ALTERNATOR ALTERNAT...

Page 4: ...ELLOW G R G B L C R LE 39 40 DIP 804 00 h 1 48 3 4 16 41 40 28 26 27 30 50 30 15 54 50 W 157 3 W MAX BELT BREAKAGE WARNING DO NOT CONNECT THE CHARGE CONTROL BULB INTO THE PLANT SEE TWIN FUNCTION INDIC...

Page 5: ...TERNATOR REGULATOR 27 ALTERNATOR REGULATOR 28 PRE EXCITATION CHARGE ALTERNATOR 40 STARTER MOTOR 41 BATTERY ON REQUEST ACCESSORIES MOUNTED ON THE ENGINE The system is arranged to command the stopping w...

Page 6: ...ONDS THE RELEVANT INDICATOR WILL LIGHT UP WITHOUT STOPPING THE ENGINE DISCONNECT THE WIRE FROM TERMINAL 8 OF THE DEVICE AND CONNECT TERMINAL 8 TO EARTH DISCONNECT THE WIRE FROM THE OIL PRESSURE SWITCH...

Page 7: ...INSUFFI CIENT PRESSURE ENGINE OVERHEATING INSUFFICIENT FUEL NORMALLY THE RELEVANT TERMINAL OF THE BATTERY CHARGE ALTERNATOR IS NEGATIVE WITH THE ENGINE STATIONARY NORMALLY THE TERMINAL OF THE OIL PRE...

Page 8: ...or lights up The overheating indicator lights up ENGINE STOPS FOR ANOMALY ENGINE DOES NOT STOP UNDER ANY CONDITIONS Stop system electromagnet or solenoid does not function Defective engine probes Defe...

Page 9: ...y replace the oil pressure switch Test and if necessary replace the thermostat Simulate the functioning of the device see DEVICE TEST on page 5 and if necessary replace it Turn the key to zero to rese...

Page 10: ...2 SEE PAGE 5 ACCESSORIES DATA FOR ORDERING MOBILE SOCKETS type PMO 134 00 code 40804234 ENGINE PROTECTION DEVICE type code type code DIP 804 00 12 V DIP 804 00 24 V 00030201 00030202 ACCESSORIES AVAI...

Page 11: ...VDC CIRCUIT LOADING WITH KEY TURNED TO ZERO 8 mA MAXIMUM LOAD ON OUTPUT 5 3 A STOP MAXIMUM LOAD ON OUTPUT 7 3 W GENERAL ALARM TEMPERATURE RANGE 10 60 C TERMINAL BOARD FASTON 6 35 0 8 DEGREE OF PROTECT...

Page 12: ...Remarks 12 GB DIP 804 00 2...