UNIT FOR CONTROL AND PROTECTION

OF IRRIGATION MOTOR PUMPSET

TYPE

CIM-250/10

Only for starting and surveillance of the diesel motor pump and stops it if there are anomalies in
the parts controlled by probes.
It has been designed to be installed also on the machine.

- Always install under other equipment which produces or spreads heat.
- Always follow the Wiring Diagram on pages 4-5 when making connections.
- Check that the line loading and the consumption of the connected equipment are compatible

with the technical characteristics on page 8.

- All technical interventions must be performed with the engine stationary and terminal 50 of

the starter motor disconnected.

- Never use a battery charger for the emergency start-up, this could damage the control unit.
- To protect the safety of persons and the equipment, before connecting an external battery

charger, disconnect the electrical plant terminals from the battery poles.

- Never disconnect the battery terminals with the engine running.

THIS CONTROL UNIT IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING
CONDITIONS:
- Where the environmental temperature is outside the limits indicated in the Technical Data on

page 8.

- Where there are high levels or heat from radiation caused by the sun, ovens or the like.
- Where there is the risk of fire or explosions.
- Where the panel can receive strong vibrations or knocks.

ELECTROMAGNETIC COMPATIBILITY
This control unit functions correctly only if inserted in plants which conform with the CE marking
standards; it meets the exemption requirements of the standard EN61326-1 but it cannot be
excluded that malfunctions could occur in extreme cases due to particular situations.
The installer has the task of checking that the disturbance levels are within the requirements of
the standards.

CONDUCTION AND MAINTENANCE
The following maintenance operations should be performed every week:

- check that the indicators function;
- check the batteries;
- check that the conductors are tight, check the condition of the terminals.

NOTICES

Warning

:

adhere closely to the following advice:

UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS CONTROL UNIT IS NOT SUITABLE FOR
USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR KEEPING PERSONS OR OTHER
LIVING BEINGS ALIVE

!

YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS CONTROL

UNIT BY TELEPHONING ONE OF OUR TECHNICIANS

Summary of Contents for CIM250/10

Page 1: ...panel the functions of hour meter oil pressure gauge water or oil thermometer tachometer pump water pressure gauge timer fuel level gauge pump protection exclusion battery and oil lights protections...

Page 2: ...PRESSURE CUMULATIVE ALARM STOP BAR PRESS UNTIL THE 2 SIGNS START FLASHING TO EXCLUDE PUMP PROTECTION TO RE ACTIVATE PROTECTION PRESS AGAIN UNTIL THEY SWITCH OFF PUMP PROTECTION IS ACTIVE WATER PRESSUR...

Page 3: ...e indicated by the relevant lights stop the engine they are memorised and can be split into two groups Delayed by 2 seconds for Delayed by 5 seconds for A1 BATTERY CHARGE ALTERNATOR ALTERNATOR BELT BR...

Page 4: ...IN STOP MODE 85 30 86 87 SOLENOID t o c l o s e the fuel WARNING IT IS NOT POSSIBLE TO MOUNT THE EMERGENCY STOP BUTTON ON A STOP SYSTEM WITH ELECTRO MAGNETS YELLOW 85 30 86 87 2 7 TACHOMETER ADJUSTME...

Page 5: ...LPROBE 173 WATER PRESSURETRANSMITTER SUPPLIED 26 PERMANENTMAGNETS CHARGEALTERNATOR 27 BATTERYCHARGEALTERNATOR REGULATOR 28 PRE EXCITATION CHARGEALTERNATOR 40 STARTING MOTOR 41 BATTERY 157 GENERALALARM...

Page 6: ...e RED GREEN wire It is activated on protection intervention The control unit comprises six instruments INSTRUMENTS WHICH CAN BE SELECTED IN SEQUENCE BY PRESSING THE BUTTON HOUR METER Total hours of op...

Page 7: ...ABLE FOR OPERATING IN THE FOLLOWING CONDITIONS Where the environmental temperature is outside the limits indicated in the Technical Data on page 8 Where there are high levels or heat from radiation ca...

Page 8: ...5 Kg 3 2 Kg BATTERYVOLTAGE SUPPLY VOLTAGE SUPPLY 32V CIRCUITLOADING WITH KEY ATZERO MAX LOAD OFTHE OUTPUT STOPPING YELLOW STARTING MOTOR BLACK GENERALALARM RED GREEN AUXILIARY BROWN TEMPERATURE RANGE...

Reviews: