BRIEF INSTRUCTIONS

After starting, the motor pump protects itself automatically

ENGINE WATER OR OIL
TEMPERATURE IS DISPLAYED

ENGINE OIL PRESSURE
IS DISPLAYED

THE FUEL LEVEL IS DISPLAYED

PRESS IF YOU WANT
TO SET WORKING
TIME ( UP TO 96

HOURS)

EMERGENCY STOP

MOTOR PUMP OPERATING
SPEED IS DISPLAYED

ACCUMULATED OPERATION
HOURS ARE DISPLAYED

PUMP WATER PRESSURE
IS DISPLAYED

A1 AVAILABLE

PRESS TO ADJUST
WATER PUMP
ELECTRONIC
PRESSURE SWITCH

THE BATTERY IS
NOT CHARGING

LOW ENGINE
OIL PRESSURE

ENGINE PROTECTIONS
ARE ACTIVE

STOPPAGE DUE TO LOW
COOLANT LEVEL

STOPPAGE DUE TO LACK OF BATTERY
CHARGING (BELT BREAKAGE)

STOPPAGE DUE TO HIGH
ENGINE TEMPERATURE

STOPPAGE DUE TO INSUFFICIENT
ENGINE OIL PRESSURE

CUMULATIVE ALARM

~

~

~

~

STOP

BAR

PRESS UNTIL THE 2 SIGNS
START FLASHING TO
EXCLUDE PUMP
PROTECTION.
TO RE-ACTIVATE
PROTECTION, PRESS AGAIN
UNTIL THEY SWITCH OFF.

PUMP PROTECTION
IS ACTIVE

WATER PRESSURE IS
REGULAR

PRESS TO SELECT THE
DISPLAYED FUNCTION,
EACH TIME IT IS PRESSED,
THE INSTRUMENT INDICATED
BY THE DISPLAY CHANGES.

STOPPAGE DUE TO LOW
FUEL LEVEL

START KEY

- OFF
- STOPPAGE IN ALL OPERATING CONDITIONS
- RESTORE PROTECTIONS, CANCEL PUMP PROTECTION EXCLUSION AND TIMER,

DEACTIVATE INSTRUMENTS.

- CONTROL UNIT SUPPLY
- TURNS ALL THE LIGHTS ON FOR 2 SECONDS ( EFFICIENCY CHECK )
- PRESSURE SWITCH ADJUSTING (SEE PAGE 3)

- MOTOR PUMP START UP

0

AUT.

AVV.

STOPPAGE
DUE TO LOW
PRESSURE
OR
PUMP WATER
OVERPRESSURE
OR
ELECTRONIC
PRESSURE GAUGE
(TRANSMITTER)
INTERRUPTED.
IN THIS CASE,
THE ANOMALY IS
HIGHLIGHTED BY
THE FLASHING
WARNING LIGHT.

LOW PRESS.

OVERPRESS.

DISCONN'ED

0

~~

~~

M

P

BAR

%

STOP

~

~

~

~

~

~

~

~

h

BAR

°C

RPM

!

A1

0

AUT.

AVV.

LOW FUEL PRESSURE

Summary of Contents for CIM250/10

Page 1: ...panel the functions of hour meter oil pressure gauge water or oil thermometer tachometer pump water pressure gauge timer fuel level gauge pump protection exclusion battery and oil lights protections...

Page 2: ...PRESSURE CUMULATIVE ALARM STOP BAR PRESS UNTIL THE 2 SIGNS START FLASHING TO EXCLUDE PUMP PROTECTION TO RE ACTIVATE PROTECTION PRESS AGAIN UNTIL THEY SWITCH OFF PUMP PROTECTION IS ACTIVE WATER PRESSUR...

Page 3: ...e indicated by the relevant lights stop the engine they are memorised and can be split into two groups Delayed by 2 seconds for Delayed by 5 seconds for A1 BATTERY CHARGE ALTERNATOR ALTERNATOR BELT BR...

Page 4: ...IN STOP MODE 85 30 86 87 SOLENOID t o c l o s e the fuel WARNING IT IS NOT POSSIBLE TO MOUNT THE EMERGENCY STOP BUTTON ON A STOP SYSTEM WITH ELECTRO MAGNETS YELLOW 85 30 86 87 2 7 TACHOMETER ADJUSTME...

Page 5: ...LPROBE 173 WATER PRESSURETRANSMITTER SUPPLIED 26 PERMANENTMAGNETS CHARGEALTERNATOR 27 BATTERYCHARGEALTERNATOR REGULATOR 28 PRE EXCITATION CHARGEALTERNATOR 40 STARTING MOTOR 41 BATTERY 157 GENERALALARM...

Page 6: ...e RED GREEN wire It is activated on protection intervention The control unit comprises six instruments INSTRUMENTS WHICH CAN BE SELECTED IN SEQUENCE BY PRESSING THE BUTTON HOUR METER Total hours of op...

Page 7: ...ABLE FOR OPERATING IN THE FOLLOWING CONDITIONS Where the environmental temperature is outside the limits indicated in the Technical Data on page 8 Where there are high levels or heat from radiation ca...

Page 8: ...5 Kg 3 2 Kg BATTERYVOLTAGE SUPPLY VOLTAGE SUPPLY 32V CIRCUITLOADING WITH KEY ATZERO MAX LOAD OFTHE OUTPUT STOPPING YELLOW STARTING MOTOR BLACK GENERALALARM RED GREEN AUXILIARY BROWN TEMPERATURE RANGE...

Reviews: