background image

35

34

NANOVIP PLUS MEM:
INTERNAL MEMORY STRUCTURE

- Storage medium utilized: 0Serial Flash Memory

type NX25F080 (NEXCOM); 8 Megabit Serial
Flash Memories managed as 2048 sectors of 536
bytes.

- Type of data recorded: 4 different measure “families”

are recorded: RMS measures, MEM measures,
PEAK measures and finally measures THD + DC
HARMONIC in pre-set intervals of 2
seconds or from 1-99 minutes.

Recording is carried out in “records” of 32 byte
defined as follows:

• RMS measures:

YY MM GG HH MM 0x01 24 Byte record data SS Check

YY MM GG HH MM 0x11 24 Byte record data SS Check

Where:

- YY, MM, DD, HH, MM are the year, month, day,

hour and minute when the record was recorded
(D1..D5);

- SS are the seconds (D31)
0x01 is the type of record: record 1, under record 0 (D6);
- Record data:

- Voltage measure (V) 

(D7..D9: base + exp)

- Current measure (I) 

(D10..D12: base + exp)

- Active Power measure (Watt) 

(D13..D15: base + exp)

- Power Factor 

(D16..D18: base + exp)

- Reactive Power measure (var)

 (D19..D21)

- Apparent Power measure (VA)

(D22..D24: base + exp)

- Frequency (Hertz) 

(D25..D27: base + exp)

- D28..D30 not used
- D32 Modbus check-sum

0x11 is the type of record: record 1, under record 1 (D6);

- Record data:

- kWh positive 

(D7..D11: bcd format)

- kvarh  positive 

(D12..D16: bcd format)

- kWh negative 

(D17..D21: bcd format)

- kvarh  negative 

(D22..D26: bcd format)

- D27..D30 not used
- D32 Modbus check-sum

• MEM measures:

YY MM GG HH MM 0x02 24 Byte record data SS Check

Where:

- YY, MM, DD, HH, MM are the year, month, day,

hour and minute when the record was stored
(D1..D5);

- SS are the seconds (D31)
0x02 is the type of record: record 2, under record

0 (D6);

- Record data:

-Voltage saved in MEM mode (V) 

(D7..D9: base + exp)

- Current saved in MEM mode (I) 

(D10..D12: base + exp)

-Active Power saved in MEM mode (Watt)

(D13..D15: base + exp)

-Power Factor stored 

(D16..D18: base + exp)

-difference in Voltage (

D

V) with respect to the

value MEM 

(D19..D21: base + exp)

-difference in Current (

D

I) with respect to the value

MEM 

(D22..D24: base + exp)

-difference in Active Power (

D

Watt) with respect

to MEM 

(D25..D27: base + exp)

-D28..D30 not used
-D32 Modbus check-sum

ENGLISH

• PEAK measures:

YY MM GG HH MM 0x02 24 Byte record data SS Check

Where:

- YY, MM, DD, HH, MM are the year, month, day,

hour and minute when the record was stored
(D1..D5);

- SS are the seconds (D31)
0x03 is the type of record: record 3, under record 0 (D6);
- Record data:

- minimum Voltage measure saved in PEAK mode

(D7..D9: base + exp)

- maximum Current measure saved in PEAK mode

(D10..D12: base + exp)

- maximum Active Power measure in PEAK mode

(D13..D15: base + exp)

- Power Factor saved in PEAK mode 

(D16..D18: base + exp)

- Reactive Power measure saved in PEAK mode (var)

(D19..D21)

- Apparent Power measure saved in PEAK mode (VA)

(D22..D24: base + exp)

- frequency saved in PEAK mode (Hertz)

(D25..D27: base + exp)

- D28..D30 not used
- D32 Modbus check-sum

Summary of Contents for NanoVIP Plus Mem

Page 1: ...Supplement to Nanovip Plus manual Supplement au manuel d instruction Nanovip Plus Erg nzung zum bedienungshandbuch Nanovip Plus Suplemento al manual de instrucciones Nanovip Plus a d v a n c e d t e c...

Page 2: ...21 20 NANOVIP PLUS MEM SUPPLEMENTTO NANOVIP PLUS MANUAL E N G L I S H...

Page 3: ...f factory setup parameters of the instrument page 25 d Display of the Active Power measure relative to the harmonic selected page 25 e Downloading through serial line of the voltage and current wavefo...

Page 4: ...he entire range of measures managed by NANOVIP PLUS with a maximum of 4032 recorded blocks of measures at intervals from 2 second to 1 99 minutes The campaigns are recorded through the menu The SETUP...

Page 5: ...es inside the data buffer where a frame is equal to an entire sampling for one signal either Voltage or Current D2 type of signal identified by the first frame D3 number of sampling data relative to f...

Page 6: ...n MEM in the display G MODBUS COMMAND FOR SETTING A DETERMINED HARMONIC The NANOVIP PLUS includes a Modbus command that allows you to set the immediate calculation of a determined harmonic The Modbus...

Page 7: ...PAG PAG PAG PAG PAG PAG PAG RSt Yes Restore factory default d o I F S F F L Backlit OFF Backlit ON Backlit On for 10 seconds at each keystroke CLr Yes Clear data memory SET CLr no SET d o I n S t F L...

Page 8: ...ry used Data recording rate PAG To MEAS PAGE PAG Hr hh mm ss PAG PAG DAY dd mm yy Clock Calendar SET SCROLL STOP PAG PAG SEL From THD I To Crest Factor V Volt mem mem Harmonic CosF Is displayed Volt A...

Page 9: ...D26 bcd format D27 D30 not used D32 Modbus check sum MEM measures YY MM GG HH MM 0x02 24 Byte record data SS Check Where YY MM DD HH MM are the year month day hour and minute when the record was stor...

Page 10: ...cord 1 D6 Record data VDC Ripple D7 D9 base exp VDC Ripple D10 D12 base exp ADC Ripple D13 D15 base exp ADC Ripple D16 D18 base exp D19 D30 not used SS are the seconds D31 D32 Modbus check sum 0x24 is...

Page 11: ...n is finished there would be the transmission of each record block requested approximately every second which is the time NANOVIP PLUS MEM takes to perform the measure To accelerate the total download...