B) DISPLAY BACKLIGHTING

The SETUP MENU is added with a Setup page on
display backlighting control with commands DISP
ON, DISP  OFF and DISP AUT (automatic
backlighting for 10 seconds at each keystroke).  The
life of the battery is about 45 hours with DISP ON
(the first five hours of which with backlighting on
and the following 40 hours with backlighting off) and
approximately double with DISP OFF.

C) RESTORE DEFAULT SETUP PARAMETERS

The SETUP MENU includes the possibility to restore
the default settings by using a command (TV ratio,
TA ratio, Configuration setup, Harmonics setup,
COM Setup).

D) DISPLAY OF ACTIVE POWER MEASURE OF

SELECTED HARMONIC

In the page displaying the RMS values relative to
the harmonic selected, there is now the possibility
to see the Active Power value (besides the values
of V, I and Power Factor) by keeping the Sel key
pressed.

24

This function allows you to store in a special flash-
type auxiliary memory (1024Kbyte) the entire range
of measures managed by NANOVIP PLUS, with a
maximum of 4032 recorded blocks of measures at
intervals from 2 second to 1...99 minutes.

The campaigns are recorded through the menu.

The SETUP MENU allows access to 4 pages for
setting data recording functions:
• Date setup
• Time setup (date and time are included at the top

of every record)

• Setup of the time interval between two recordings

(every 2 seconds, or at  intervals of 1...99 minutes)

• Deletion of recorded data.

In the LOG CTRL MENU the recording of the
measure campaigns can be activated or deactivated;
this menu also displays the percentage recorded in
memory and the programmed rate of recording.
Once activated, the data LOG continues until it is
either deactivated or the memory is full: during this
time the part of the Setup menu relative to the LOG
(see the block diagram on the menu pages) is
deactivated; if the device is turned off and then
tur ned on again recording star ts again.

In the MEAS PAGE two more pages are included
with display of the date and time.

To download data by serial line, see the dedicated
section.

A) RECORDING OF MEASURE CAMPAIGNS

(operation)

ENGLISH

Summary of Contents for NanoVIP Plus Mem

Page 1: ...Supplement to Nanovip Plus manual Supplement au manuel d instruction Nanovip Plus Erg nzung zum bedienungshandbuch Nanovip Plus Suplemento al manual de instrucciones Nanovip Plus a d v a n c e d t e c...

Page 2: ...21 20 NANOVIP PLUS MEM SUPPLEMENTTO NANOVIP PLUS MANUAL E N G L I S H...

Page 3: ...f factory setup parameters of the instrument page 25 d Display of the Active Power measure relative to the harmonic selected page 25 e Downloading through serial line of the voltage and current wavefo...

Page 4: ...he entire range of measures managed by NANOVIP PLUS with a maximum of 4032 recorded blocks of measures at intervals from 2 second to 1 99 minutes The campaigns are recorded through the menu The SETUP...

Page 5: ...es inside the data buffer where a frame is equal to an entire sampling for one signal either Voltage or Current D2 type of signal identified by the first frame D3 number of sampling data relative to f...

Page 6: ...n MEM in the display G MODBUS COMMAND FOR SETTING A DETERMINED HARMONIC The NANOVIP PLUS includes a Modbus command that allows you to set the immediate calculation of a determined harmonic The Modbus...

Page 7: ...PAG PAG PAG PAG PAG PAG PAG RSt Yes Restore factory default d o I F S F F L Backlit OFF Backlit ON Backlit On for 10 seconds at each keystroke CLr Yes Clear data memory SET CLr no SET d o I n S t F L...

Page 8: ...ry used Data recording rate PAG To MEAS PAGE PAG Hr hh mm ss PAG PAG DAY dd mm yy Clock Calendar SET SCROLL STOP PAG PAG SEL From THD I To Crest Factor V Volt mem mem Harmonic CosF Is displayed Volt A...

Page 9: ...D26 bcd format D27 D30 not used D32 Modbus check sum MEM measures YY MM GG HH MM 0x02 24 Byte record data SS Check Where YY MM DD HH MM are the year month day hour and minute when the record was stor...

Page 10: ...cord 1 D6 Record data VDC Ripple D7 D9 base exp VDC Ripple D10 D12 base exp ADC Ripple D13 D15 base exp ADC Ripple D16 D18 base exp D19 D30 not used SS are the seconds D31 D32 Modbus check sum 0x24 is...

Page 11: ...n is finished there would be the transmission of each record block requested approximately every second which is the time NANOVIP PLUS MEM takes to perform the measure To accelerate the total download...

Reviews: