8
Technical Data Sheet
Duoblock Dual Fuel Burner
Feld52:
RPD 90 / 100 GL-R / GS-R
42000
45000
7000
7000
0
5000
10000
15000
20000
25000
30000
35000
40000
45000
50000
RPD 90
RPD 100
kW
Technical Data
Fuel flow rate (light oil)
Gas flow rate
Operating mode
Fuel type
Automatic burner controller
Flame sensor
Ignition burner
Ignition transformer
Pump output at 35 bar
MAT oil control block
Oil connection
Nozzle rod
Nozzle
Actuator
Gas connection
Weight
Pressure loss in mixing unit
Gas control organ
Burner output
Output range
7000 - 42000 kW
RPD 90
590 - 3540 kg/h
700 - 4200 m³/h
fully modulating
Light oil / heavy oil / natural gas / special fuels
LFL 1. , LGK 16 or other approved models
QRA 2, QRA 53 or other approved models
MAT / Hegwein ZNVL (ZT0)
D-52 L5 KV
Z112 K5
8900 l/h
SRB 19000/90
R 1" / 28 mm
MAT
MAT - MK 50
WAN 5 A
R 8"
1400 kg
30 mbar or according to diagram
according to gas pressure
(MAT ignition burner)
(Hegwein ignition burner)
7000 - 45000 kW
RPD 100
590 - 3800 kg/h
700 - 4500 m³/h
9500 l/h
SRB 19000/90
R 1"/ 28 mm
MAT
MAT - MK 50
WAN 5 A
R 8"
1450 kg
Technical Data Sheet
Duoblock Dual Fuel Burner
RPD 90 & 100 GL-R / GS-R