Installation
For the realisation of concentric
air/flue gas systems the use of
original accessory parts by ELCO-
Klöckner is recommended.
Kits for connection of the air/ flue gas
pipes are supplied separately from the
appliance depending on the various
installation options.
The heating appliance is preset for
connection to a concentric air/flue gas
system.
Connection of the heating appliance
to the flue is effected for all appliance
with the aid of concentric hose pipes
ø 80/125 or via double hose systems
ø 80/80.
For each 90° change of alignment 1,5
m of the total hose length must be
deducted.
The additional resistance obtained
thereby must be taken into account in
the previously mentioned sizing.
16
Air-flue gas routing
Conducting variants and Dimensioning
Type of flue gas connection
Max. length of flue gas
pipes (m)
Pipe diameter (mm)
24 HSG/HG (30 HSG/HG*)
Minimum
Maximum
concentric
systems
C13x
0,7
15,7
ø 80/125
B33
0,7
15,7
ø 80/125
Double hose
systems
C13x C33x C43x
0,5=S1 : 0,5=S2
20=S1 : 20=S2
ø 80/80
C53x C83x
1=S1 : 0,5=S2
1=S1 : 32=S2
ø 80/80
B23
0,5=S2
33=S2
ø 80
Type of flue gas connection
Max. length of flue gas
pipes (m)
Pipe diameter (mm)
12 HG/18HG
Minimum
Maximum
concentric
systems
C13x
0,7
15,7
ø 80/125
B33
0,7
15,7
ø 80/125
Double hose
systems
C13x C33x C43x
0,5=S1 : 0,5=S2
20=S1 : 20=S2
ø 80/80
C53x C83x
1=S1 : 0,5=S2
1=S1 : 32=S2
ø 80/80
B23
0,5=S2
33=S2
ø 80
Conducting variants and sizing
*) only for Belgium
S1
Combustion air is equivalent to the length in metres of the air intake hose
S2
Flue gas routing is equivalent to the length in metres of the flue gas hose