Indoor Installation
Corner Setup
with Noise Dampers
20
AEROTOP T20-35 Corner Setup
The dimensions of the noise dampers
must be considered in addition when
placing AEROTOP T07 to T35 heat
pumps into a corner.
The heat pump can be placed in the
right or left corner. Air ducts are not
needed.
Required Accessories:
-
WAI wall setup, suction side
-
WAO wall setup, output side
-
SI nose damper
-
SO noise damper
1) The compliance with acoustic limit
values must be clarified by
customer.
2) Necessary outside insulation by
customer, minimal clearance of
light well must not be gone below.
3) Possible air short-circuit to be
prevented by customer.
4) Statistics to be checked by
Customer
5) Distance from wall: min 20 mm,
max 40 mm
AEROTOP T
Width Width Heigh
Dimensions With
Noise Dampers
Dimensions Of Both Cutouts,
Without Insulation
Minimal Dimensions,
Light Well
a b c A
C a2 c2 d2 e2 x a3 c3 a4 c4
T07C,
T07 995 1525 650 1570 1225 950 600 640
860
635
1200
600 800 600
T10C,
T10
1095 1575 750 1670 1325 1050 700 640 910 635 1200 600 1000 600
T12, T14,
T16
1195 1575 750 1770
1325 1150 700 640 1010 635 1200 600 1000 600
T20,
T26
1195 1675 880 1770 1455 1150 830 740 930 635 1400 800 1200 800
T32,
T35
1295 1695 1000 1870 1575 1250 950 740
1140
635
1400 800 1200 800
•
Statistics to be checked by
customer If necessary wall must
be reinforced with PUR- insulation
elements. This must be considered
for the cutouts
The indicated cutouts apply only to the
accessories AIR IN and OUTLET wall
setup. The dimensions apply after all
tasks have been completed and refer
to finished floors.
•
Possible air short-circuit to be
prevented by customer
•
Necessary outside insulation to
be installed by customer