Elbro AG 980 255 909 Manual Download Page 1

 

Detector 3000 

Seite 0 / 11 

Stand: 29.8.19 GB 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAT III / 1000V  

CAT IV / 600V 

 

 

 

 

 

EN 61326-1 

IEC 61243.3:2014 

 

 

 

 

 

 

 

 

 

 

 

 

EN  Manual

 

DETECtOR 3000

 

 

universaltester 
électrotesteur 
elettrotester 
electrical tester 

Summary of Contents for 980 255 909

Page 1: ...Detector 3000 Seite 0 11 Stand 29 8 19 GB CAT III 1000V CAT IV 600V EN 61326 1 IEC 61243 3 2014 EN Manual DETECtOR 3000 universaltester lectrotesteur elettrotester electrical tester...

Page 2: ...9 8 19 GB 1 Opening for current measurement 2 Test leads on back side 3 LED display 4 LCD display 5 On off and function button 6 Torchlight and hold button 7 Battery compartment 8 Sensor for cable bre...

Page 3: ...or in instruction manual Warning of a potential danger comply with instruction manual Reference Please pay utmost attention Caution Dangerous voltage Danger of electrical shock Continuous double or re...

Page 4: ...e and reliable working It complies with the standard for two pole voltage testers EN61243 3 2014 The Detector 3000 is characterized by the following features Designed to meet international safety stan...

Page 5: ...cted to be disconnected of the installation it is highly recommended confirming by another means e g use of an adequate voltage tester visual check of the disconnecting point of the electric circuit e...

Page 6: ...g transport leaking batteries The tester complies with all EMC regulations Nevertheless it can happen in rare cases that electric devices are disturbed by the electrical field of the tester or the tes...

Page 7: ...for tests 6 1 Auto power on switching on The tester switches on when it detects shorten tips or an AC or DC voltage above approx 6V or a live phase on L2 single pole test It can be switched on with a...

Page 8: ...n center of the opening at the height of the markings left and right Make sure that only double insulated cables are measured Store test probes safely to avoid any unintended connection Tester switch...

Page 9: ...y LED lights up buzzer sounds continuously and Con symbol on LCD is on if L1 tip is connected on Anode of diode and L2 tip on Cathode Continuity indication will be off if L1 tip is connected on Cathod...

Page 10: ...s before shortening tips 7 12 HOLD Function Long press 2 seconds on torchlight function button activates HOLD function and freezes display value With short press on torchlight function button freezing...

Page 11: ...40 70Hz Safety current Is 3 5mA at 1000VAC Measurement Duty 30s ON operation time 690V 10s ON operation time 690V 240s OFF recovery time Internal battery consumption Approx 120mA Single pole phase tes...

Page 12: ...est points before cleaning Use a lightly damp cloth with neutral detergent for cleaning the instrument Do not use abrasives or solvents Do not expose the instrument to direct sun light high temperatur...