Before connecting to the mains, make sure that:
1) The electrical counter, the safety valve, the feeding line and the socket are
adequate to with stand the maximum load required (see rating plate).
2) The supply system is regularly grounded, according to the regulations in force.
3) The socket or the omnipolar switch can easily be reached after the installation of
the oven. After carrying out the connection to the mains, check that the supplying
cable does not come into contact with parts subject to heating.
4) Never use reductions, shunts, adaptors which can cause overheating or burning.
5) The manufacturer is not liable for any direct or indirect damage caused by faulty
installation or connection. It is therefore necessary that all installation and
connection operations are carried out by qualified personnel complying with the
local and general regulations in force.
ELECTRICAL FEATURES
Oven light
25W
Upper heating element
1950W
Bottom heating element
1800W
Grill heating element
2250W
Circular heating element
1800W
Ventilator motor
30W
Cooling fan
11W
VENTILATION
In general, the appliance should have adequate ventilation for complete
combustion of gas, proper flueing and to maintain temperature of immediate
surroundings within safe limits.
GAS CONNECTION
The appliance must be connected to the gas supply or the cylinder according to the
specifications of the standards and after checking that it is adjusted for the type of
gas available. Once the appliance has been installed, make sure that the gas pipe
is neither squashed nor damaged by moving parts.
Before Leaving, check all
connections for gas leaks with soap and water. DO NOT use a naked flame for
detecting leaks. Ignite all burners both individually and separately to ensure correct
operation of gas valves, burners and ignition.