background image

25

TABLE FOR THE CHOICE OF THE INJECTORS Cat: 

III

BURNERS

Nominal

Power

[kW]

Reduced

Power

[kW]

LPG

G30 28 mbar

Natural Gas

G20 18 mbar

Town Gas

G110 8 mbar

Ø injector

[1/100 mm]

Ø injector

[1/100 mm]

Ø injector

[1/100 mm]

Semirapid (SR)

1,75

0,45

65

97 (Z)

190 (2)

Triple Ring (TR)

3,50

1,50

95

135 (T)

340 (6)

AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m

3

/h x kW)

BURNERS

Air necessary for combustion [m

3

/h]

Semirapid (SR) (*)

3,50

Triple Ring (TR)

7,00

LUBRICATION OF THE GAS TAPS

The operations must be executed by a qualified technician.

IMPORTANT: All intervention regarding installation maintenance and conversion of 

the appliance must be fulfilled with original factory parts.

The manufacturer declines any liability resulting from the non-compliance of this 

obligation.

GAS MAINTENANCE

Summary of Contents for ELIO 75-300

Page 1: ...Made in Italy 100 ELBAQUALITY MADE IN ITALY BUILT IN COOKING HOBS Model ELIO 75 300 Instructions for the use Installation advices...

Page 2: ...lease preserve this booklet carefully It may be useful in future either to yourself or to others in the event that doubts should arise relating to its operation This appliance must be used only for th...

Page 3: ...traps etc should not be left around within easy reach of children as these may cause serious injuries Some appliances are supplied with a protective film on steel and aluminium parts This film must be...

Page 4: ...age shall be kept away unless continuously supervised This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of exp...

Page 5: ...hob Do not scratch the hob with sharp objects Don t use the hob as a work surface WARNING If the hob is cracked or otherwise damaged by falling objects etc disconnect the appliance from the electrical...

Page 6: ...stopped if and when the flame should accidentally go out CAUTION If the burner is accidentally extinguished turn the gas off at the control knob and wait at least 1 minute before attempting to religh...

Page 7: ...ti clockwise to point the indicator towards the small flame symbol Other intermediate operating adjustments can be achieved by positioning the indicator between the maximum and minimum aperture positi...

Page 8: ...mount of time since the capacity of heat absorption of a liquid mass depends on the volume and the surface of the pot LIGHTING THE BURNERS To ignite the burner the following instructions are to be fol...

Page 9: ...woks should be placed over the pan rest for the triple ring burner Warning Using woks without this special grille may cause the burner to malfunction Do not use the grille for ordinary flat bottomed s...

Page 10: ...a wok stand as this will concentrate and deflect the heat onto the hotplate Do not use large pots or heavy weights which can bend the pan support or deflect the flame onto the hotplate Locate pan cen...

Page 11: ...can scratch the surface which may result in shattering of the glass Remove spillages and other types of incrustations by using only specific products which do not contain abrasives or chlorine based a...

Page 12: ...t the probe T figs 3 3 3 6 next to each burner is always clean to ensure correct operation of the safety valves Both the probe and ignition plug must be very carefully cleaned Note To avoid damage to...

Page 13: ...e level and must not rotate Failure to do so can cause serious problems The pan support shall be correctly positioned as indicated in fig 3 4 The pan supports shall be level and must not rotate Be sur...

Page 14: ...y positioned must not rotate Then position the cap A and the ring B figs 3 5 and 3 7 They shall be level The pan support shall be correctly positioned as indicated in fig 3 8 The pan support shall be...

Page 15: ...s The four holes around the outside of the burner cup must always be kept clean This is necessary to ensure the correct and safe operation of the burner When cleaning remove the flame spreader use a c...

Page 16: ...ommended when handling or cleaning of this appliance Always disconnect the appliance from mains power supply before carrying out any maintenance operations or repairs These tops are designed to be emb...

Page 17: ...mm away from any side wall fig 4 2 at least 215 mm between the side of the cutout and the side wall fig 4 1 There must be a distance of at least 60 mm between the back side of the cutout and the back...

Page 18: ...Cut the unit according to the dimensions in fig 4 1 Turn the hob upside down and rest the glass side on a soft surface Spread the seal G around the edge of the hob fig 4 4 Fasten the brackets R to the...

Page 19: ...t they cannot be blocked from either the inside or the outside When these openings cannot be made the necessary air can come from an adjacent room which is ventilated as required as long as it is not...

Page 20: ...allations Failure to install the appliance correctly could invalidate any manufacturer s warranty This appliance is supplied for use on LPG It is adjusted for this gas only and cannot be used on any o...

Page 21: ...SO 228 1 female Hose holder for NATURAL GAS or TOWN GAS Hose clamp not supplied Rubber hose not supplied for NATURAL or TOWN GAS connection internal diameter 13 mm Rubber hose not supplied for LPG con...

Page 22: ...ter 13 mm The hose must comply with the applicable local regulations and be of the correct construction for the type of gas being used 3 Make sure that the hose is tightly and securely fitted at both...

Page 23: ...injectors are correct for the type of gas being used If not follow the instructions under GAS MAINTENANCE replace the sealing washer s on the slightest sign of deformation or imperfection The sealing...

Page 24: ...which the plug of the flexible hose fit is permanently attached to a firmly fixed gas installation pipe and is positioned so that the hose hangs freely downwards the plug of the flexible hose is acce...

Page 25: ...T 340 6 AIR VENT NECESSARY FOR GAS COMBUSTION 2 m3 h x kW BURNERS Air necessary for combustion m3 h Semirapid SR 3 50 Triple Ring TR 7 00 LUBRICATION OF THE GAS TAPS The operations must be executed b...

Page 26: ...ooktop Using a wrench substitute the injectors J figs 5 3 5 4 with those most suitable for the kind of gas for which it is to be used The burners are conceived in such a way so as not to require the r...

Page 27: ...ectly to the mains it must be placed with an omnipolar switch with minimum opening between the contacts of 3 mm between the appliance and the mains The power supply cable must not touch the hot parts...

Page 28: ...with plug and outlet Connection with wall box connection WARNING If the power supply cable is damaged it must be replaced only by an authorised service agent in order to avoid a hazard The supply cabl...

Page 29: ...29...

Page 30: ...30...

Page 31: ...31...

Page 32: ...g or transcription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacturer commercial reasons at any moment and wi...

Reviews: