background image

 

8

REMOVING MINERAL BUILD-UP 
 

It is common for minerals found in hard water to build up inside the appliance, causing 
intermittent or weak steam. If you do not use de-mineralized or distilled water in your 
steamer, follow these steps monthly: 

1.  Turn the unit off, and unplug the power cord. 
2.  Remove the hose and telescopic pole from the unit. 
3.  Drains the water reservoir by unfasten the drainage valve. Empty water from the water tank. 
4.  Mix a solution of 50% vinegar and 50% water. In most cases, 2 cups of this solution will be 

sufficient. 

5.  Slowly pour the water-vinegar solution into the hose connector. 
6.  The water-vinegar solution will becomes visible in the water reservoir’s inlet hole, continue 

to pour the solution into the hose connector until it is full, monitor from the hose inlet. 

7.  Allow the water-vinegar solution in the hose connector for 40 minutes. 
8.  After that, drain the solution out of the water reservoir by removing the drainage valve to 

allow the liquids to drain into a sink. 

9.  Drain the remaining solution out from the hose connector by tilting the unit over a sink. 
10. Pour clean water into the hose connector and water reservoir inlet and drain again. Repeat 

this step until the vinegar odor dissipates. 

11. Reassemble the unit and operate normally. 
 

If this procedure does not return the unit normal operation, the unit may need servicing. 

 
TROUBLE SHOOTING   
 
Problem   

Reasons   

Solution   

The unit fails to steam. 
The indicating lamps did 
not light up. 
 

The appliance is not plugged in. 
 

Connect the plug to the wall 
outlet and power on. 

Household circuit breaker / ground 
fault interrupter is tripped or fuse is 
blown. 

Check the power outlet. If you 
need assistance, contact a 
qualified electrician. 

The unit fails to steam. 
The indicating lamp is on. 
 

Mineral built-up in the unit. 
 

Refer to the removing mineral 
build-up.   

The water tank is empty. 

Refill the water tank. 

Excessive gurgling of 
hose and steam nozzle. 
 

Condensation in hose. 

Some gurgling is a natural 
effect of the steam process. 
For excessive gurgling, 
extend the hose vertically to 
allow water to drain back into 
the water reservoir. 

Steam is intermittent. 
 

Mineral build-up in the unit. 

It’s normal for the unit to 
periodically stop steaming for 
a few seconds. If the steam 
stays off for longer periods, 
follow the removing mineral 
build-up procedure. 

 
 

Summary of Contents for EGSI-C1540

Page 1: ...fully before operating your set Retain it for future reference Record model number and serial number of the set See the label attached on the set and quote this information to your dealer when you req...

Page 2: ...escopic pole Do not force the casters if they are struck Drain the water from water tank and water reservoir before inspecting the casters 13 Allow the appliance to cool completely for at least 30 min...

Page 3: ...Cloth hanger hook 10 Water reservoir 2 Steam head 11 Rolling casters 3 Handle 12 Folding rack 4 Telescopic pole 13 Clips 5 Hose 14 Holding nips 6 Pole base 15 Drainage valve 7 Hose base 16 Fabric brus...

Page 4: ...prevent scalding 2 The telescopic pole must be fully extended during steam operation to ensure smooth lining of the hose and provide a free flow of steam 3 Do not pull the hose with excessive force o...

Page 5: ...es until two bars F are on the same straight line and completely extended as per figure 9 and 10 5 Push and lock the sleeve G in place by aligning the dot on the bar F in figure 11 HOLDING NIPS AND CL...

Page 6: ...ssion turn the switch in the OFF position and power off the appliance Remove the plug from the outlet USING THE FABRIC BRUSH 1 To steam a garment place it on a clean rust free clothes hanger and place...

Page 7: ...AINTENANCE We recommend you follow this procedure at least once per week 1 Turn the switch to OFF position and power off the appliance 2 Unplug the unit from the wall outlet 3 Allow the steam head to...

Page 8: ...y tilting the unit over a sink 10 Pour clean water into the hose connector and water reservoir inlet and drain again Repeat this step until the vinegar odor dissipates 11 Reassemble the unit and opera...

Page 9: ...9...

Reviews: