22
GAS MAINTENANCE
LUBRICATION OF THE GAS TAPS
•
In case of difficulty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be fulfilled with
original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.
TABLE FOR THE CHOICE OF THE INJECT
ORS
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30 28-30 mbar
G31 37 mbar
Natural Gas
G20 20 mbar
Town Gas
G1
10 8 mbar
Ø injector
[1/100 mm]
Ring
opening
[mm]
Ø injector
[1/100 mm]
Ring
opening
[mm]
Ø injector
[1/100 mm]
Ring
opening
[mm]
Auxiliary (A)
1,00
0,40
50
-
77
-
145
-
Semi-rapid (SR)
1,75
0,45
66
-
101
-
192
-
Rapid (R)
3,00
0,75
87
-
129
-
280
-
Oven
3,20
0,85
86
Fully open(*)
130
5 (*)
270
5 (*)
(*) = Reference value
AIR VENT
NECESSAR
Y FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semi-rapid (SR)
3,50
Rapid (R)
6,00
Oven
6,40