35
Before effecting any intervention on
the electrical parts of the appliance,
the connection to the network must be
interrupted.
Fig. 9.1
PE
N
L
1
(L
2
)
Fig. 9.2
ELECTRICAL FEEDER CABLE CONNECTION
The operations must be executed by a qualified technician.
To connect the supply cable:
•
Remove the screws securing the cover “
A
” on the rear of the cooker (fig. 9.1).
•
Feed the supply cable through the cable clamp “
C
” (fig. 9.1). The supply cable must
be of a suitable size for the current requirements of the appliance; see the section
“Feeder cable specifications”.
•
Connect the wires to the terminal block “
B
” as shown in the diagram in figure 9.2.
•
Take up any slack in the cable and secure with the cable clamp “
C
”.
•
Replace the cover “
A
”.
Note: The earth conductor must be left about 3 cm longer than the others.
FEEDER CABLE SPECIFICATIONS
230V~ or 220-240V~
AWG 14/3
(*) (**)
or
230V~ or 220-240V~
Type H05RR-F 3 x 0,75 mm
2
(*) (**)
(*) Connection possible with plug and
outlet
(**) Connection with wall box connection.
A
B
C
230 V~ or 220-240 V~
Summary of Contents for E 8550FG2 Series