15
Selftest
claw type: the claw type will be measured by turning on
each claw type has a specific number:
0 = error
2 = small
3 = medium
4 = large
5 = big one
Problems with the wiring or claw can be the basic source of
wrong results. Press “T” to measure again. The number
has to correspond with the number of your claw type.
Cord replacement: two functions can be done:
1 replacing the string:
•
Press “T”
•
Lead the string until it’s unwound completely.
•
Place the new string correctly around the wheels (you may block the motor), hook up
the string in the cutout of the string winder and pull slightly until the string starts to
wind up.
•
The motor will stop automatically…finished!
2. release a wrong winded up string:
•
Press T,
•
The motor will release the string and unwind the pulley so that the claw reaches the
bottom.
•
Now place the string manual on its correct position.
•
Press “T” again and lead the string by rolling up.
mech cycle: a complete test of the mechanical cycle (SW4 will not be tested).
lamp test: the lamps of the controls flash one at the time
dispenser: the optional dispenser pays out 1 consolation prize
coin in: control of coin/bill acceptor
ctrl: control of the switches from push buttons/joystick
gantry-in: control of the switches on the gantry
extension: control of extensions f.ex: IR-detection
data in: control of the intelli link
The information lines above indicates if the input to the Intelli controller is activated
(=I) or not (=O). The inputs are counted from the right to the left.
If an input changes, it has to be visible only on 1 position!
This menu will help you to localize and possibly solve a problem.
SELFTEST
T clawtype 3
T cord replacement
T mech. cycle
T lamptest
T dispenser
i coin-in 00000000
i ctrl 00000000
i gantry-in00000000
i extension00000000
i data in (ad=0) 0