background image

 

                                             

15

                        

www.elationlighting.com

  

       

             

 

ELATION© PLATINUM 1200 WASH™ S Y S T E M    M E N U 

Features are subject to change without any prior written notice. 

Supports Software Versions: ≥ 2.1.0 

MAIN MENU 

SUB MENU 

OPTIONS / VALUES 

(Default Settings in

 BOLD

)

 

   

FUNCTION 

Set DMX Address 

001

~xxx 

DMX Address Setting 

DMX Value 

ALL…… 

DMX Value Display 

Slave Mode 

Slave1, Slave2, Slave3 

Slave Setting 

Auto Program 

Master / 

Alone

 

Auto Program 

INFORMATION 

Time Information 

Current Time 

XXXX (Hours) 

Fixture Run Time From Power ON 

Total Run Time 

XXXX (Hours) 

Fixture Total Run Time 

Last Run Time 

XXXX (Hours) 

Clear Fixture Last Run Time 

LastRun Password 

Password=XXX 

Password 

038

 

Clear Last Run 

ON / 

OFF

 

Reset Fixture Last Run Time 

Temperature Info 

Head Temperature 

XXX C° / 

F °

 

Temperature in Fixture Head 

Ethernet IP 

XXX . XXX . XXX . XXX  XXX . XXX . XXX . XXX  IP Address 

Fan Speed 

FAN1:xxx RPM, FAN2:xxx RPM, FAN3:xxx RPM 

Displays RPM Speeds of Fans 

Software Version 

1U01: - 3U01: 

Vx.x.x

 

Software Versions 

Error Info 

Error Record 1 ~ Error Record 10 

Displays Last 10 Error Codes 

PERSONALITY 

Status Settings 

Address via DMX 

ON

/OFF 

Address Via DMX 

No DMX Status 

Hold

/Close Shutter/ 

Auto Program 

Auto Run If No DMX 

Pan Reverse 

ON/

OFF

 

Pan Reverse Movement 

Tilt Reverse 

ON/

OFF

 

Tilt Reverse Movement 

Pan Degree 

630/

540

 

Pan Degree Select 

Feedback 

ON

/OFF 

Movement Feedback 

Movement Speed 

Speed 1

, 2, 3, 4 

Select Movement Speed   

Zoom Range Mode 

Mode 1

, Mode 2 

Select Zoom Range Mode   

Hibernation 

OFF, 01M~99M,

 

15M

 

Stand By Mode 

Service Setting 

Password 

Password=

050

 

Service Password 

RDM PID 

XXXXX 

RDM PID Code 

Ethernet IP 

XXX . XXX . XXX . XXX  Ethernet IP 

Ethernet Mask IP 

XXX . XXX . XXX . XXX  Ethernet Mask IP 

Clear Err. Info 

ON/

OFF

 

Clear Error Code History 

Fans Control 

Auto

, Low, High 

Set Fan Speed 

Display Setting 

Shutoff Time 

02~60m 

05m

 

Display Shut Off Time 

Flip Display 

ON/

OFF

 

Flip/Invert Display 180º 

Key Lock 

ON/

OFF

 

Key Lock 

Disp Flash 

ON

/OFF 

Display Flashes When No DMX Signal 

Temperature C/F 

Celsius/

Fahrenheit

 

%08;0<,>?<0$A4>.30>A009JJ 

Initial Status 

PAN =XXX 

Initial Effect Position 

Dimmer Modes 

Standard

, Stage, TV, Architectural, Theatre 

   

Select Signal 

DMX Only 

DMX Only 

Art-Net on IP2 

Elect Art-Net IP02 

Art-Net on IP10 

Elect Art-Net IP010 

sACN 

sACN Protocol 

Set Universe 

000 - 255 

Set Art-Net Universe 

Refresh 

1200

, 900-1500, 2500, 4000, 5000, 10000, 

15000, 20000, 25000 (Hz)

 

Set Refresh Rate 

Gamma 

2.0, 

2.2

, 2.4, 2.6, 2.8 

Set Gamma Value 

Reset Default   

ON/

OFF

 

Password 

011

 

Restore Factory Settings 

NOTE: Saved White Balance 

Erased!

 

Summary of Contents for PLATINUM 1200 WASH

Page 1: ...PLATINUM 1200 WASH user manual E L A TI ON PLATINUM 1200 WASH user manual...

Page 2: ...erty equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or...

Page 3: ...ormation 4 Warranty 6 Safety Instructions and Guidelines 7 Overview 9 Installation 10 System Menu 14 DMX Channel Functions And Values 22 LED Pixel Control 30 Error Codes 31 Cleaning and Maintenance 33...

Page 4: ...thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged careful...

Page 5: ...ice items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief des...

Page 6: ...nal if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this warranty does not include...

Page 7: ...y the original rigging parts omega brackets included with this fixture should be used for installation Any modifications to the fixture and or the mounting hardware included will void the original man...

Page 8: ...o less than M10 x 25 mm and always install fixture with an appropriately rated safety cable Always disconnect fixture from main power source before performing any type of service and or cleaning proce...

Page 9: ...I E W 1 LED Lens Array 2 LCD Menu Function Display 3 MODE ESC Button 4 LEFT Button 5 DOWN Button 6 ENTER Button 7 RIGHT Button 8 UP Button 9 RJ45 Ethernet IN 10 5pin DMX IN 11 RJ45 Ethernet OUT 12 5pi...

Page 10: ...xture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 to 113 F 10 to 45 C Do not...

Page 11: ...pletely locked CLAMP INSTALLATION When mounting fixture to truss be sure to secure an appropriately rated professional grade rigging clamp to the included Omega Brackets using an M10 screw fitted thro...

Page 12: ...ial and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is fully operational in the specific mounting po...

Page 13: ...abit Ethernet Switch that supports IGMP Internet Group Management Protocol is required Using a Gigabit Ethernet Switch that does not support IGMP can cause erratic behavior of all connected devices to...

Page 14: ...the different functions and access the sub menus with the UP DOWN RIGHT and LEFT buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and...

Page 15: ...o Program Auto Run If No DMX Pan Reverse ON OFF Pan Reverse Movement Tilt Reverse ON OFF Tilt Reverse Movement Pan Degree 630 540 Pan Degree Select Feedback ON OFF Movement Feedback Movement Speed Spe...

Page 16: ...nes via Ext DMX Console Rec Controller XX XX Automatic Scenes Recorder PERSONALITY Status Settings Address Via DMX When ON define the desired fixture DMX address via an external controller NOTE This p...

Page 17: ...X starting address are no longer needed This is especially useful when the device is installed in a remote area RDM ready and conventional DMX devices can be operated in one DMX line The RDM protocol...

Page 18: ...all adjustments to be made to the Pan Tilt and Zoom movements to compensate for ware or in the event a sensor has been knocked slightly out of place Because improper use of this function can result in...

Page 19: ...t is set to Slave 1 in the menu Set to Slave the Master unit sends Auto Program Part 1 to the Slave unit If set to Slave 2 the Slave unit receives Auto Program Part 2 To start an Auto Program proceed...

Page 20: ...master units U J KK ENTER to confirm U J KK MODE ESC in order to return to the main menu 4 Program Selection for Edit Program U D L ZEdit Program U J KK ENTER to confirm U D L Edit Program U J KK ENT...

Page 21: ...needs to be calibrated to match as much as possible Once a new White Balance preset is saved to the fixture the maximum dimmer intensity values cannot be changed until the White Balance preset is upda...

Page 22: ...e Control of TILT Movement 3 5 RED ALL PIXELS 0 255 Red 0 Black 255 100 6 RED FINE ALL PIXELS 0 255 Red FINE Adjustment 4 7 GREEN ALL PIXELS 0 255 Green 0 Black 255 100 8 GREEN FINE ALL PIXELS 0 255 G...

Page 23: ...UE PIXEL 1 0 255 Blue 0 Black 255 100 8 WHITE PIXEL 1 0 255 White 0 Black 255 100 9 RED PIXEL 2 0 255 Red 0 Black 255 100 10 GREEN PIXEL 2 0 255 Green 0 Black 255 100 11 BLUE PIXEL 2 0 255 Blue 0 Blac...

Page 24: ...0 255 Red 0 Black 255 100 30 GREEN PIXEL 7 0 255 Green 0 Black 255 100 31 BLUE PIXEL 7 0 255 Blue 0 Black 255 100 32 WHITE PIXEL 7 0 255 White 0 Black 255 100 33 RED PIXEL 8 0 255 Red 0 Black 255 100...

Page 25: ...55 Blue 0 Black 255 100 52 WHITE PIXEL 12 0 255 White 0 Black 255 100 53 RED PIXEL 13 0 255 Red 0 Black 255 100 54 GREEN PIXEL 13 0 255 Green 0 Black 255 100 55 BLUE PIXEL 13 0 255 Blue 0 Black 255 10...

Page 26: ...55 Red 0 Black 255 100 70 GREEN PIXEL 17 0 255 Green 0 Black 255 100 71 BLUE PIXEL 17 0 255 Blue 0 Black 255 100 72 WHITE PIXEL 17 0 255 White 0 Black 255 100 73 RED PIXEL 18 0 255 Red 0 Black 255 100...

Page 27: ...5 79 SALMON all LEDs 80 84 TURQUOISE all LEDs 85 89 LIGHT GREEN all LEDs 90 94 STEEL BLUE all LEDs 95 99 ORANGE all LEDs 100 104 STRAW all LEDs 105 109 PALE LAVENDER all LEDs 110 114 PINK all LEDs 115...

Page 28: ...Pixel Ring 47 62 Outside Pixel Ring 63 78 Center Pixel Inside Pixel Ring 79 94 Inside Outside Pixel Rings 95 110 All Pixels 111 126 Chase 1 127 142 Chase 2 143 158 Chase 3 159 174 Chase 4 175 190 Chas...

Page 29: ...93 SPECIAL FUNCTIONS INTERNAL PROGRAMS 0 79 Color Change Normal 80 84 ALL MOTOR RESET 85 87 SCAN MOTOR RESET 88 90 NO FUNCTION 91 93 EDIT and SAVE WHITE BALANCE ENABLED 94 96 NO FUNCTION 97 99 OTHER...

Page 30: ...L E D P I X E L C O N T R O L A L L P I X E L N U M B E R S LCD CONTROL DISPLAY LCD CONTROL DISPLAY Pixel control depends on PAN TILT position of head L E D P I X E L C O N T R O L P I X E L R I N G...

Page 31: ...and 05Er flash repeated 5 times If an error does occur during the initial start up procedure the fixture will self generate a second reset signal and try to realign all the motors and correct the erro...

Page 32: ...ocked during a reset function TILT The TILT movement is not located in the default position after the reset This message will appear after a fixture reset if the magnetic indexing circuit malfunctions...

Page 33: ...issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspect...

Page 34: ...ONS 3 DMX Channel Modes 20 26 32 Adjustable Refresh Rate 900 1500 2500 4000 5000 10000 15000 20000 25000 Hz Adjustable Gamma Brightness 2 0 2 2 2 4 2 8 RDM Remote Device Management 6 Button Touch Cont...

Page 35: ...1 890 176 BLUE 1 970 183 1 525 142 879 82 437 41 WHITE 23 700 2 202 10 070 936 6 126 569 2 795 260 FULL ON 41 730 3 877 20 700 1 923 11 210 1 041 5 285 491 MAX ZOOM 77 Beam Diameter 5 m 16 4 ft 7 5 m...

Page 36: ...www elationlighting com 36 DIMENSIONAL DRAWINGS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice...

Page 37: ...A C C E S S O R I E S ORDER CODE ITEM TRIGGER CLAMP Heavy Duty Wrap Around Hook Style Clamp TBA Road Case For PLATINUM 1200 WASH AC5PDMX5PRO 5 ft 1 5m 5pin PRO DMX Cable CAT6PRO5 5 ft 1 5m CAT6 EtherC...

Page 38: ......