background image

 

 

 

 

 

 

 

 

 

 

 

 

E SPOT LED II™ 

user manual 1.0

   

   

EL

A

TI

O

N

 

|

 

SP

O

T L

ED

 II

 

|

 

us

e

r m

a

n

ua
l 1

.0

 

Summary of Contents for E Spot Led II

Page 1: ...E SPOT LED II user manual 1 0 E L A TI ON E SPOT LED II user manual 1 0...

Page 2: ...wledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all lia...

Page 3: ...nformation 4 Warranty 6 Safety Instructions 7 General Guidelines 8 Fixture Overview 9 Installation 10 Understanding DMX 13 Fixture Menu 17 DMX Channel Functions And Values 39 Error Codes 42 Cleaning a...

Page 4: ...ery E SPOT LED II has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton app...

Page 5: ...y or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well...

Page 6: ...t forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional w...

Page 7: ...warranty and increase the risk of damage and or personal injury Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness Those suff...

Page 8: ...e sure no air ventilation slots are blocked Do not attempt installation and or operation without proper knowledge how to do so Do not permit operation by persons who are not qualified for operating th...

Page 9: ...X T U R E O V E R V I E W 1 LED Assembly 2 LCD Menu Function Display 3 Mode Esc Button 4 UP Button 5 DOWN Button 6 ENTER Button 7 Microphone 8 Carrying Handle s 9 3Pin DMX Output 10 3Pin DMX Input 11...

Page 10: ...ety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture Be sure the fixture is kept at least 0 5m 1 5 feet away from an...

Page 11: ...e mounting bracket assembly that integrates the bottom of the base the included Omega Bracket and the safety cable rigging point in one unit see the illustration below When mounting this fixture to tr...

Page 12: ...choose for your E SPOT LED II always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be...

Page 13: ...ine with a Y style connector The order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of 1 may be placed...

Page 14: ...ovided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the E SPOT LED II The diagram below illustrates a typical DMX 512 connection when the fixture i...

Page 15: ...nd DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a line terminator will decrease the possibilities of erratic behavior 5...

Page 16: ...channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of...

Page 17: ...l operation pressing the MODE ESC key once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN butt...

Page 18: ...s the tilt movements 7 FINE ON OFF Switch 16 bit 8 bit 8 DEGR 540 630 Pan degree select 9 MIC M XX M 70 Mic sensitivity 10 DISP VALU D XX D 00 DXXX Display the DMX512 value of each channel D ON ON OFF...

Page 19: ...e digit address will immediately begin to flash 3 While the current three digit address is flashing press UP and DOWN to select adjust the address Lock your new address into the unit s memory by press...

Page 20: ...l RUN is displayed press ENTER 4 Press UP or DOWN to select Master or Alone and press ENTER 5 Press MODE ESC to return to the main menu AUDI This feature is used to run the internal preset programs in...

Page 21: ...that position until it is turned off or begins receiving a new DMX signal If the fixture is turned on without any DMX signal the fixture will automatically go in to sound active mode Available settin...

Page 22: ...ess UP until COLR is displayed then press ENTER to confirm 4 Press MODE ESC to return to the main menu GOBO When you activate this reset function only the Gobo Wheel motor is reset 1 Access the main m...

Page 23: ...ote Please clear the LED time every time you replace the LED 1 Access the main menu 2 Press UP until TIME is displayed press ENTER 3 Press UP until CLMP is displayed press ENTER 4 Press MODE ESC the d...

Page 24: ...return to the main menu 7 FINE MENU This menu item switches between 16bit fine and 8bit coarse modes When this function is turned on the fixture will operate in 16bit fine mode When functioning in 16...

Page 25: ...5 Press ENTER to confirm 6 Press MODE ESC to return to the main menu 9 MIC MENU This function allows for electronic control of the internal microphone s sound sensitivity 1 Access the main menu 2 Pres...

Page 26: ...splayed 3 Press ENTER the display will show VALU 4 Press UP until D ON is displayed and press ENTER Press UP to select ON to activate this function or OFF to deactivate this function When set OFF this...

Page 27: ...5 Press UP to select ON to activate or OFF to deactivate this function 6 Press ENTER to confirm 7 Press MODE ESC to return to the main menu 11 SPEC MENU This menu option access all the special functi...

Page 28: ...to return to the main menu DFSE With this function you can restore the factory default settings of the fixture All settings will be set back to the default values Any edited scenes will be lost When r...

Page 29: ...IGH or AUTO 6 Press ENTER to confirm 7 Press MODE ESC to return to the main menu Hibernation When activated this function will put the fixture in power stand by mode This function will automatically a...

Page 30: ...yed then press ENTER 3 Press UP or DOWN until CODE is displayed then press ENTER 4 The display will show CXXX were as XXX represents the calibration password The calibration password is C050 Use UP or...

Page 31: ...ur programs into STXX SC01 SC48 These are the Scenes 48 total stored in your program C 01 C 11 Channel 1 Channel 11 Represents the total fixture channels for each scene that can be edited TIME Time Ru...

Page 32: ...le and will remain in the fixture s memory even when the power to the unit is switched off Memory is backed up and retain by an internal power source that should last about five years Remote DMX addre...

Page 33: ...starting address between 256 and 511 3 Use Channel 3 to set your desired DMX starting address 4 Wait for approximately 20 seconds for the unit to complete the address reset function Example 1 If you w...

Page 34: ...how without the need of an external controller The fixtures will react to sound chasing to a synchronized light show Set To Slave This function will set the fixture to slave mode for use in either the...

Page 35: ...access the Set To Slave settings in the Function Mode menu and assign each slave fixture a designation Slave 1 Slave 2 Slave 3 etc Universal DMX Control This function allows you to use a universal DM...

Page 36: ...program can store one or a maximum of 64 scenes Keep in mind that a scene can only be access when it is stored in a Program If you wish to build a static scene a scene consisting of no movement for a...

Page 37: ...be Dimmer adjust the dimmer intensity Scene Time set the hold time for the scene Input By Out this function will store a scene from an external DMX console See the next section for scene editing via a...

Page 38: ...tomatically lock the selected scene into the programs memory Repeat the process until all the desired scenes have been added to the program Each program can store a maximum of 64 scenes To test the pr...

Page 39: ...w w w e l a t i o n l i g h t i n g c o m 39 E SPOT LED II User Manual 1 0 D M X C H A N N E L F U N C T I O N S A N D V A L U E S...

Page 40: ...w w w e l a t i o n l i g h t i n g c o m 40 E SPOT LED II User Manual 1 0...

Page 41: ...w w w e l a t i o n l i g h t i n g c o m 41 E SPOT LED II User Manual 1 0...

Page 42: ...rrected the fixture will make the following determinations 1 3 or more errors The fixture cannot function properly with three or more errors therefore the fixture will place itself in a stand by mode...

Page 43: ...on the main PCB Rotating Gobo Indexing Error The gobo is not located in the default position after start up or after a reset command This message will appear after a fixture reset if the gobo positio...

Page 44: ...to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A...

Page 45: ...0 100 COLOR 8 Dichroic Colors White GOBOS 7 Interchangeable Rotating Indexing Glass Gobos Size OD 27mm ID 22mm CONTROL CONNECTIONS 2 DMX Channel Modes 12 14 3pin 5pin DMX In Out 4 Button Control Pane...

Page 46: ...ments in the design of this unit and this manual are subject to change without any prior written notice ROTATING GOBOS 1 4 FULL ON 15 Beam Angle LUX x 0 0929 FC 0 m 0 ft 5 m 16 4 ft 2 5 m 8 2 ft 7 m 2...

Page 47: ...mprovements in the design of this unit and this manual are subject to change without any prior written notice Note Please add 3 76 5mm to the total height of the fixture when using the included Omega...

Page 48: ...n l i g h t i n g c o m 48 E SPOT LED II User Manual 1 0 CIRCUIT SCHEMATICS Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any pri...

Page 49: ...DMX Cable AC3PDMX15PRO 15 ft 4 5m 3pin PRO DMX Cable AC3PDMX25PRO 25 ft 7 5m 3pin PRO DMX Cable AC3PDMX50PRO 50 ft 15m 3pin PRO DMX Cable AC3PDMX100PRO 100 ft 30m 3pin PRO DMX Cable AC5PDMX5PRO 5 ft...

Page 50: ...w w w e l a t i o n l i g h t i n g c o m 50 E SPOT LED II User Manual 1 0...