7.5.4
Set Configuration Register „og‟
Use this command to set the Configuration registers of the reader. In contrast to the EEPROM
registers, the settings of the „og‟ command are volatile, this means they are taking effect on the
behavior of the reader at once and they are lost, when a reset occurs or the reader is powered down.
Command:
‘og[RegAddr][Value]’
Answer
Answer
Description
Data<CR><LF>
Value of the modified register
‘R<CR><LF>’
Error: Register out of range
Register address
Description
03h
Reset Off Time
04h
Reset Recovery Time
08h
AFI
Example
Command
Description
og0310
Set Reset Off Time to 10h (16ms)
og0420
Set Reset Recovery Time to 20h (32ms)
7.5.5
Set Tag Type „oa‟ / „ob‟ / „op‟ / „os‟ / „ot‟ / „ov‟
Use this command to search for only one specific transponder type (e.g. only ISO14443A). In contrast
to the EEPROM registers, the settings of the „o‟ command are volatile, this means they are taking
effect on the behavior of the reader at once and they are lost when a reset occurs or the reader is
powered down.
Command:
‘oa’ / ‘ob’ / ‘op’ / ‘os’/ ‘ot’ / ‘ov’
Answer
Answer
Description
‘OA<CR><LF>’
Search for ISO14443A transponders
‘OB<CR><LF>’
Search for ISO14443B transponders
‘OP<CR><LF>’
Search for PicoPass / ICLASS transponders
‘OS<CR><LF>’
Search for SRX transponders
‘OT<CR><LF>’
Search for all supported transponders
‘OV<CR><LF>’
Search for ISO15693 transponders